0+95.)()%+.5503+24
Chemical attack
Filter material degrades due to attack from certain chemicals in the dust
or gasses in the air stream.
High moisture
High moisture content in the collector may cause certain filter cartridge
material to shrink, degrade (more rapidly at elevated temperatures) or
blind off.
Localized abrasion
Abrasion of the filter cartridges where high velocity dusty air hits the filter
cartridges. A dust impingement baffle may be required to be installed on
the inlet of the dust collector.
0+95.)()- 0
Check for mechanical damage.
If the “Power On” indicator is not on, check for proper power input. The
“hot” line connection must be connected to terminal “L1”, as this is the
fused terminal.
Check for a blown fuse; if replacement is necessary, use only 3 AMP
standard 3AG fuse (1-1/4” long). Do not use a slow-blow type fuse.
Check the wiring from the timer to the solenoids for open or short
circuits.
After performing the steps above, if the timer is still not functioning
properly (no output voltage, sequencing problems, etc.) please contact
your CAMCORP representative.