Section 7 – Routine Maintenance
Inspection
Frequency will vary as widely as there are operating conditions. In
general proceed as follows:
Daily – Check unit differential pressure.
Weekly Check pulse timer board and solenoid valves for function.
This usually is only listening to verify uniform time in intervals between
blasts.
Monthly Lubricate fan, rotary valve and screw conveyor. Check seals
on latter two for dust loss.
Repairs
Filter cartridges Generally replacement, although some applications
can be laundered.
Solenoid Valves Repair kits are available if a valve is stuck open or
fails to operate.
Diaphragm Valves Repair kits are available if a valve is stuck open or
fails to operate due to a ruptured diaphragm.
Rotary Valves Usually a matter of periodic seal and blade
replacement. More detailed information is supplied with the valve.
Screw Conveyors Periodic replacement of “V” belts and shaft seals.
Inspect hanger bearings during filter bag change. Failure will be
detected by the squeal.
Fans “V” belt tension and replacement of bearings if running rough.
Make sure rotor balance is maintained.
7-1