Installation Instructions
Page 1 of 7
Lazerpoint™ RF RX-90v2
Advanced Single Relay Receiver
INSTALLATION INSTRUCTIONS
Door Activation Devices
1. DESCRIPTION
CM-RX-90v2 receivers can be paired with Lazerpoint™ or
Kinetic™ transmitters, switch selectable.
Kinetic™ by Camden is an advanced 900 MHz 'power harvesting'
wireless system that uses the energy created by the operation
of the switch to power the wireless transmitter.
This Kinetic™ transmitter is available with the following push
plate switches: CM-45K, CM-46K, CM-7536K and CM-7509K.
Lazerpoint™ Radio Controls comprise the following models:
• CM-TX-9 Wall switch ready transmitter
• CM-TX-99 Plug-in transmitter
• CM-TXLF 1, 2 & 4 button fob transmitters
• CM-RX-90v2 Advanced single relay receiver
• CM-RX-91 Basic single relay receiver
• CM-RX-92 Full function (dual relay) receiver
Lazerpoint™ RF is the rst system designed to address the
specic needs of the Automatic Door industry. Unlike typical
“garage door” RF, Camden’s Lazerpoint™ operates at 915 MHz
frequency to “cut through” noise and clutter, penetrating typical
building materials to ensure a reliable installation.
Three receiver models are offered – the basic single relay RX-91,
the full function RX-92 and the advanced single relay RX-90v2.
The RX-90v2 offers 3 operating modes including delayed, no
delay and latched.
The CM-RX-90v2 supports both Lazerpoint™ RF and
Kinetic™ by Camden transmitters.
CM-RX-90v2 features a convenient terminal block, visual relay
status, and 40 code memory with push and learn technology.
2. FEATURES
• 3 Modes of Operation:
- Delayed (1 - 15 Seconds)
- No Delay (1 – 30 Seconds)
- Latching
• Adjustable Range: 3' - 300'
• 40 Transmitter capacity, either Lazerpoint™ or Kinetic™
either delayed, non-delayed or both
• Form ‘C’ Relay Output
• 12/24V AC/DC operation
• 915 MHz Lazerpoint™ or Kinetic™ Technology
• Small Size: 2-5/8”H x 1-1/2”W x 13/16”D (67mm x 38mm x 21mm)
3. SPECIFICATIONS
Operating Voltage 12/24V AC/DC
Current Draw
23 mA nominal @ 24 VAC
43 mA maximum @ 24 VAC
Response Time 30 – 200 ms
Memory Delay
& No Delay
40 transmitters total
LED’s
Indicate: relay status; learn mode;
erase mode & potentiometer position
Output 1 x SPDT Relay contact
Rating 3 amps @ 30 VDC
Operating Time 1 – 30 seconds
Delay Time 1 – 15 seconds
Frequency 915 Mhz.
Mounting 2-#4 screws at 3” centers or Velcro (supplied)
Enclosure Clear plastic case
Dimension 2-5/8”H x 1-1/2”W x 13/16”D
(67mm x 38mm x 21mm)