4. INSTALLATION
MOUNTING
The RX-90v2 receiver is designed to mount inside the automatic
door header. Screw holes are located at each end of the receiver
case, or the included velcro may also be used to hold it securely.
For dimensional information refer to RX-90v2 electrical and
mechanical Drawing on Page 4.
WIRING
Note: Do not use the Kinetic/Lazerpoint RF system as a safety
device! If safety devices are used, always wire directly to the
operator control box.
Refer to the RX-90v2 Wiring Diagram on Page 5, and wire the
receiver as follows:
Wire the device (electric lock / operator) to the Relay output -
terminal 3 is N.O. 4 is Common and 5 is N.C.
Connect 12 or 24V AC/DC
to terminals 1 & 2 on the
receiver. (Terminals are
not polarity sensitive)
5. SET-UP INSTRUCTIONS
Note: Some switches that have more than one transmitter
(CM-7536(K)) will have to have both individually learned into the
CM-RX90v2. This will affect how many devices can be learned in
since the total number of transmitters per CM-RX90v2 is 40 and
not 40 devices.
STEP 1
Learning the Transmitter(s) to the Receiver
A receiver can have up to 40 transmitters paired with it. The
transmitter can be paired as Kinetic™/ Lazerpoint™ delayed,
non-delayed or a combination of both, making RX-90v2 ideal
for bi-directional door sequencing.
Set the RF Transmitter Type
Set DIP2 to ON Kinetic™, DIP2 to OFF Lazerpoint™
Learning the Transmitter in Delayed Mode
Set DIP1 to ON.
Press PB1 using a small blunt object such as a small blade
screwdriver or similar. Within 10 seconds, press the switch
connected to a TX-9 transmitter or a button on a Lazerpoint™
FOB or Kinetic™ switch. The Green LED Array ashes to conrm
enrollment. Repeat with any additional transmitters. Pressing
the learned transmitter again will signal the receiver that you are
nished programming and the LED will ash rapidly.
Pressing the transmitter a third time activates the relay, LED, and
the device connected to the relay contacts after the delay time
set by POT1. If you wait longer than the 10 second period, the
receiver times out of Learn Mode and reverts back to standby.
Learning the Transmitter in No-Delay Mode
Set DIP1 to OFF
Press PB1 using a small blunt object such as a small blade
screwdriver or similar. Within 10 seconds, press the switch
connected to a TX-9 transmitter or a button on a Lazerpoint™
FOB or Kinetic™ switch. The Green LED Array ashes to conrm
enrollment. Repeat with any additional transmitters. Pressing the
learned transmitter again signals the receiver that you are nished
programming and the LED will ash rapidly.
Pressing the transmitter a third time will activate the relay, LED, and
the device connected to the relay contacts. If you wait longer than
the 10 second period, the receiver times out of Learn Mode and
reverts back to standby.
STEP 2
Adjustments
The delay before operate and relay On-Time are controlled by POT1.
Delayed Mode
The RX-90v2 has a delay before operate timer.
Set DIP1 to ON.
Adjust POT1 clockwise to increase the delay timer from 0 to 15
seconds. The LED lights and become brighter as the delay time
is increased and becomes dim as the delay time is decreased.
The LED starts to ash once the maximum delay time has been
reached. Back off the delay time until the LED is solid again for
maximum delay time.
No-Delay Mode
The RX-90v2 can be adjusted to activate the output relay without
a delay. The relay On-Time is adjustable from 1 to 30 seconds.
Set DIP1 to OFF.
Adjust POT1 Clockwise/counterclockwise to adjust the relay
On-Time (1 to 30 Seconds). To increase the time, turn the pot
clockwise, or for minimum time, turn the pot counterclockwise.
The LED lights and becomes brighter as the Relay On-Time is
increased. The LED starts to ash once the maximum On-Time
has been reached. Back off the POT until the LED is solid again for
maximum On-Time.
2
ON
1
POT1 PB1
DIP 1
DIP 2
Terminal Description
1
Power in
2
Power in
3
Normally Open
4
Common
5
Normally Closed