Installation Instructions

LAZERPOINT™ RF RX-90v2 ADVANCED SINGLE RELAY RECEIVER
INSTALLATION INSTRUCTIONS
Page 3 of 7
Latching Mode
The RX-90v2 has a latching mode. Activating the transmitter will
latch the output relay ON. Activating the transmitter a second
time will latch the Relay OFF.
DIP1 can be set to either ON/OFF.
Adjust POT1 clockwise until the LED starts to ash. RX-90v2 is in
latching mode at this point. To remove latching mode, turn POT1
counter clockwise until the LED is solid again.
Note: Latching mode disables delayed mode. Transmitter
programmed as delayed mode will work as latching
mode transmitter.
Signal Strength Adjustment
For the most reliable, consistent operation, leave the signal
strength at full power. RX-90v2 receiver has an adjustment RF
range from a few feet to full range (300 ft. LOS).
To adjust the RF range:
1. Press PB1 to enter pairing mode.
2. Press PB1 again until the LED ickers 3 times. This places
the receiver in RF range adjust mode.
3. Adjust POT1 to adust the RF range. CW to increase the range,
CCW to decrease the range.
4. Press a paired transmitter to test range as it is being adjusted.
5. Once the desired range is set, Press and hold PB1 until LED
ickers 3 times. The transmitter is now back in pairing mode.
Either wait for the receiver to time out or press a paired
transmitter to exit pairing mode. After adjusting the range you
MUST adjust POT 1 for relay timing at this point based on the
mode (delay or no-delay).
STEP 3
DELETING TRANSMITTERS
Delay Mode Transmitters
Set DIP1 to ON.
Pressing and holding PB1 for 8 seconds deletes all transmitters
delay mode. LED ashes rapidly for 4 seconds, indicating erasure
of the codes.
No Delay Mode Transmitters
Set DIP1 to OFF.
Pressing and holding PB1 for 8 seconds deletes all transmitters
no delay mode. The LED ashes rapidly for 4 seconds, indicating
erasure of the codes.
Note that individual removal of specic codes is not possible.
6. WARRANTY
Camden Door Controls guarantees the Lazerpoint™ RF to be free
from manufacturing defects for 3 years from date of sale.
If during the rst 3 years a Lazerpoint™ RF component fails to
perform correctly, it may be returned to our factory where it will be
repaired or replaced (at our discretion) without charge.
Except as stated herein, Camden extends no warranties expressed
or implied regarding function, performance or service.
NOTE: Batteries are exempt from this warranty!