Installation Instructions

Page 11 of 15
CX-12 PLUS DOOR INTERFACE RELAY
INSTALLATION INSTRUCTIONS
FILENAME: CX-12PLUS-Diagram4a.ai
DRAWING No: DRG-CX-12PLUS-04a
CX-12PLUS Application Diagram (typical Momentary Operation)
SCALE: NONE
DRAWN BY: DGW REVISED: 1/28/2020DATE: 11/16/09
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
Electric Strike
Dry Input
(ie. Push Switch)
Wet Input
(ie. Radio Receiver)
Wire MOV
(supplied)
directly to strike
or magnet
Power
for Strike
DRY2WET2DRY1WET1POWER
NO
NO
NC
NC
COM
COM
Relay2Relay1
CX-12 PLUS
CAMDEN DOOR CONTROLS
Door Operator
Radio
Receiver
3 - Term.
24V
Com
Radio
1 52 3 4 6 7 8 9 10 11 12 13 14 15 16
RL1 RL2
DOR
RL1
DOO
RL2
DOR
RL2
OFF / ON
1
2
3
+
-
MOV
12/24 V
AC/DC
Power