Spec Sheet

SPECIFICATIONS DIMENSIONS
VOLTAGE: 12/24V AC/DC
CURRENT DRAW: 20 mA Idle
60 mA Operating
RESPONSE TIME: 0.3 Seconds
INPUTS: 2 Wet, & 2 Dry, N.0.
OUTPUTS: 2 x Form C (SPDT)
CONTACT RATING: 3 Amps @ 30V DC
ELECTRICAL LIFE TIME: 100,000 @ Rated Capacity
MODES: 8
TIME DELAY D.O.R. #1: 1-30 Seconds
D.O.O. #2: 1-30 Seconds
D.O.R. #3: 1-30 Seconds
DIMENSIONS: 3-1/4"W x 2-5/16"H x 11/16"D
(83mm x 58mm x 18mm)
1
2
34 56
78 9
10
11 12
13
14 15
16
RL1R L2
D.O.R.
RL1
D.O.R.
RL2
D.O.O.
RL2
OFF - ON
OFF - ON
1
2
1
2
Door Interface Relay
3
3
CX-12 PLUS
ORDERING INFORMATION
Door Interface Relay
CX-12PLUS
Door Interface Relay
(8) Programming modes with (3) adjustable time delays, each up to 30 seconds
(2) Dry, (2) Wet inputs, and (2) SPDT Form ‘C’ outputs
Activation Switch
Dip Switch Selection of Factory
Default Operation Mode
Relay #2 LED IndicatorRelay #1 LED Indicator
RL1 Delay on Release
RL2 Delay on Operate
RL2 Delay on Release
Activation
Switch
Occupancy / Motion Sensor
Access Control, Time Clock
or Telephone Entry System
2
nd
Door Operator
in Vestibule Application
Electric Strike or
Magnetic Lock
Fire Alarm /EVAC System
OR OR
POWER
RELAY1
RELAY2
WET1
WET2DRY1
DRY2
Camden
NO
COM
NC
1
2
3 4 5 6
7 8 9
10
11 12
13
14 15
16
NO
COM
NC
RL1 RL2
D.O.R.
RL1
D.O.R.
RL2
D.O.O.
RL2
OFF - ON
OFF - ON
1
2
3
1
2
3
Door Interface Relay
CX-12 PLUS
Door Operator
Door Operator
12/24 V
AC/ DC
Power
FIRE ALARM
Opening New Doors to
Innovation, Quality and Support!
5502 Timberlea Blvd. Mississauga, ON Canada L4W 2T7 • Toll Free: 1 877 226-3369 (CAMDEN9)
Tel: (905) 366-3377 • Fax: (905) 366-3378 • E-mail: info@camdencontrols.com • www.camdencontrols.com
Part #: MKTG-LIT-SP-CX-12PLUS
APPLICATIONS
The CX-12 PLUS Interface Relay is ideal for control and integration of automatic doors utilizing electro-mechanical
locks (including electric strikes and magnetic locks) in any commercial, institutional and multi-unit residential
application. Operating modes support bi-directional sequencing of two vestibule doors, basic restroom control, both
secured and unsecured, a maintained output for fire alarm integration, and a telephone entry panel input that
simplifies wiring, and eliminates the need for an isolating relay.