Set up
Apply power to the CX-22 and observe the LED’s.
Pot DOR/RL1 adjusts the Lock release time (up to 30
seconds). The Pot marked DOO/RL2 adjusts the
delay before the Door operator relay fires, and the
Operator hold time is adjusted with Pot DOR/RL2.
Normally Unlocked Mode:
Press the exterior wall switch. If the washroom is
unoccupied the door will open automatically. After
entering the washroom, wait for the door to close,
then push the “Lock” button. The CX-22 will energize
the lock, and remove the outside wall switch from the
circuit.
To exit the washroom, two options are available:
1. To have the door unlock and open
automatically, push the interior wall switch.
This also resets the relay for the next person
to use.
2. Manual use. The door may also be used
manually. To exit the washroom, turn the
lever handle and pull (push) the door open.
The magnet switch resets the relay for the
next person to use.
If a CM-9600 switch is used with this system, you can
connect the LED’s using a CM-9600C harness. Wire
as per Diagram #4.
If using an “OCCUPIED WHEN LITsign, such as our
CM-30-OWL, wire as per Diagram #5.
Normally Locked Mode:
In this situation the door is always locked from the
exterior.
Enter code or swipe card. The door unlocks and
after the adjustable delay, opens the door. After
entering the washroom, wait for the door to close,
then push the “Lock” button. You will hear a brief
double click of the strike indicating the door is now
locked, and the outside access control device is
removed from the circuit.
To exit the washroom, two options are available:
3. To have the door unlock and open
automatically, push the interior wall switch.
This also resets the relay for the next person
to use.
4. Manual use. The door may also be used
manually. To exit the washroom, turn the
lever handle and pull (push) the door open.
The magnet switch resets the relay for the
next person to use.
Once the desired operation is achieved, proceed to
Section 4, for System Inspection Instructions.
Section 4 _________________
System Inspection Instructions
After the Installation and operational check of the
system:
1. Place warning label on the door (as per ANSI
A156.10 or A156.19 guidelines). This will
advise the person entering the swing side
zone that the door will move.
2. Instruct the owner on door system operation
and how to test it. This should be checked
on a daily basis.
3. Instruct the owner on what to do if the door or
any of its components become damaged.
4. Strongly recommend to the owner that the
complete entry be inspected twice a year as
part of the service agreement.
Section 5_________________
Technical Data
Model CX-22
Size 3 ¼” x 2 ¼” x ¾”
Mounting Velcro or double-sided tape
Enclosure Protective paper sleeve.
Operating voltage 12 / 24 Volts, AC / DC
Current Draw 18 mA standby,
40 mA max.
Response time 0.3 seconds
Inputs 2 x “dry” contacts,
2 x “wet” contacts:
(3-30 V AC/DC, Optically
isolated, non-polarity sensitive).
Relay Output 2 x Form C (SPDT)
Relay contact rating 3 amps @ 24 VDC/120 VAC
Time Delays 3 @ 1 to 30 seconds each
Electrical Life 100,000 operations
@ rated capacity
500,000 operations
@ ½ rated capacity
Section 6_________________
Warranty
Camden Door Controls guarantees the CX-22 to be free
from manufacturing defects for 3 years from date of sale.
If during the first 3 years the CX-22 fails to perform
correctly, it may be returned to our factory where it will be
repaired or replaced (at our discretion) without charge.
Except as stated herein, Camden extends no warranties
expressed or implied regarding function, performance or
service.
Questions?
Call us toll-free at 1-877-226-3369
Page 3 of 8