FROG SERIES IN-GROUND OPERATOR FOR SWING GATES INSTALLATION MANUAL FROG-A 230V / FROG-AV / FROG-AE English EN
“IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS” “CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY” “THIS MANUAL IS ONLY FOR PROFESSIONAL OR QUALIFIED INSTALLERS” 1 Legend of symbols ENGLISH This symbol tells you to read the section with particular care. This symbol tells you what to say to the end-users. 2 Intended use and application 2.1 Intended use The FROG operator was engineered to power residential and condominium swing gates.
4.3 Dimensions 67 60 ENGLISH Pag. 3 - Manual code: 119AS45 ver. 3. 3.33 06/2008 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users. 160 405 330 5 Installation Installation must be carried out by expert qualified personnel and in full compliance with current regulations. 5.
ENGLISH 3 1) FROG unit 2) Control panel 3) Safety photocells 4) Radio receiver 5) Key-switch selector 6) Antenna 7) Command push-buthon panel 8) Flashing light 9) Photocell column 10) Shunt box 11) Transmitter 8 6 TX 10 5 1 RX 9 4 4x1,5 2 2x1 4x1 3x1 7 RG58 2x1,5 RX 5x1 4x1 3x1,5 1 4x1,5 TX 3 230V 10 9 2x1 11 5.5 Assembly diagram 67 67 160 100 60 3 Fig.2 5.
Fig.4-1 SX Pag. 5 - Manual code: 119AS45 ver. 3. 3.33 06/2008 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users. Fig.4 C C A A B B SX Fig.4-2 DX DX 5.7 Manual release - In emergencies (i.e. power outages) the release mechanisms allow the gate to hook back up when closing.
7 Safety instructions Important safety instructions Do not allow children to play or loiter within the opening/closing arc of the operator. Keep remote controls and any other command device out the reach of children, to prevent operator from being activated by accident.In the event of anomalous behaviour, stop using the operator immediately. Danger of crushing hands Danger! High voltage Danger of crushing feet No transit during operation Pag. 6 - Manual code: 119AS45 ver. 3. 3.
8 Maintenance Periodic maintenance to be carried out by the end-user is as follows: wipe clean the glass surface of the photocells; check that the safety devices work properly; remove any obstructions. We suggest checking the state of lubrication and tightness of the anchoring screws on the operator. To check the efficiency of the safety devices, move an object in front of the photocells when gate is closing. If the operator inverts the motion or stops, the photocells are working properly.
Periodic maintenance log (for end-user) (every 6 moths) Segnature 8.3 Extra-ordinary maintenance The following table serves to note down any extraordinary maintenance, repairs or improvements performed by specialised firms. N.B.: Any extraordinary maintenance must be performed by specialised technicians.
Installer’s stamp Operator name Date of job Technician’s segnature Pag. 9 - Manual code: 119AS45 ver. 3. 3.33 06/2008 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.