SERIE VER Documentazione Tecnica T44 rev. 1.
GENERAL SPECIFICATIONS Description Completion accessories Automatic traction system for overhead and sectional doors. Designed and built entirety by CAME Cancelli automatici S.p.A., in full compliance with current safety standards. IP 40 protecting rating. Guaranteed for 24 months, unless tampered with by unauthorized personnel. V201 - Transmission adapter arm for counterweighted overhead doors (it substitutes the arm supplied), see p.5. Versions V900E - Encoder controlled 24V (D.C.
EXEMPLES OF APPLICATIONS COUNTERWEIGHTED OVERHEAD DOOR, outward vertical stroke and partially inward entry type A * H SPRING-BALANCED OVERHEAD DOOR, spring balanced, outward vertical stroke and totally inward entry type B H SECTIONAL DOOR C single sliding rail double sliding rail H H - 100mm H UNIT ASSEMBLY PREARRANGEMENT OF TRANSMISSION RAIL - Fasten the bracket to the transmission guide’s front terminal with the screws provided; M6 M6x20 3
TRANSMISSION RAIL FASTENING - Fasten the transmission rail in the following manner: a) for sectional doors C-type (see ref. p.4), fasten the bracket directly over the spring-release coiling shaft using adequate dowels and screws; if the distance between the coiling shaft and the gate’s upper ledge is between 30 and 60 cm, apply the V122 arm (read the technical documentation provided with the accessory); b) for A-B-type overhead doors (see ref. p.4), verify the maximum door sliding point (fig.
SLIDING LEVER FASTENING - Centrally fix the transmission arm to the door’s upper crosspiece with the rivets provided (or possible screws); - Move the sliding runner and hook it to the transmission arm after removing the preset screw. N.B.: if the adapter arm (V201) is used, hook the carriage to the sliding runner. GEARMOTOR INSTALLATION - Remove the automation container cover by unscrewing the ø3.
ZL56 CONTROL PANEL Technical description The card is powered with a 230V (AC) power outlet and its input is protected with a 1.6A line fuse. The motor is protected with a 7,5A fuse. Control systems are powered by low voltage and protected by a 315mA fuse. The total power consumption of 24V accessories (which are protected by a 3.15A fuse) must not exceed 40W. Fixed operating time of 80 sec.
ELECTRICAL CONNECTIONS L N L N M N + 10 - 11 10 E 1 2 2 C1 2 7 M N + E - 10 11 E 1 2 N.B. All the contacts and push-buttons normally closed (N.C.) that are not used must be short-circuited. 7 C1 230V (a.c.) power supply 24 (d.c.) motor Powering accessories (max 40W) - 24V (A.C.) with power supply at 230V (A.C.) - 24V (D.C.) with power supply at 24V (A.C.) 24V output in motion (e.g. 25 W max. flashing light) Pushbutton stop (N.C.) Contact (N.C.
ENCODER PROGRAMMING IMPORTANT: READ INSTRUCTIONS CAREFULLY BEFORE PROCEEDING WITH PROGRAMMING. closure limit switch Set dip-switch 1 to ON: the red LED comes on, at slow intermittence. Keep the “AP-CH” button pressed and allow the overhead door to reach the limit switch when it closes. Press and release the “ENC/RADIO” button: the signalling LED remains on to indicate thet the closing end-stop has been saved. T.C.A. FUS. MOTORE 7.5A M N + E - SENS. AP / CH APRE ENC/RADIO 1 2 FUS. ACC.
opening limit switch Keep the “APRE” button pressed and allow the door to open fully. Press and release the “ENC/RADIO” button: the signalling LED remains on to indicate that the closing end-stop has been saved. With the door open, position the end-stop (in the transmission guide) on the sliding runner and secure it with the screws. Set dip-switch 1 to OFF. Note: if the LED indicator begins to flash rapidly after dip 1 has been reset, it is necessary to repeat the procedure from the start.
RADIO CONTROL INSTALLATION PROCEDURE A - Insert an AF card**. B - Encode transmitter/s. C - Store code in the motherboard. A - AF board insertion T.C.A. FUS. MOTORE 7.5A + E - M N AP / CH APRE ENC/RADIO 1 2 TOP AF board TAM FUS. ACC. 3,15A 26V17V 0V SENS. ON FUS. CENTR. 315mA ZL56 (**) On AM transmitters operating at 433.92 MHz (TOP and TAM series), position the jumper connection on circuit card AF43S as shown on the sheet.
TOP T432M - T312M set the code to dip-switch C and channel to D (P1=CH1 and P2=CH2, default setting) P1 D P2 P1 1 2 3 1 4 CH1 1 2 3 4 5 6 7 8 1 2 3 CH3 CH2 2 1 4 3 4 CH4 P2 C 1 4 4 3 2 3 2 9 1 2 3 4 1 2 3 1 4 10 CH1 2 3 CH3 CH2 2 1 4 3 4 CH4 C - Code storage - Keep the “ENC/RADIO” key pressed on the base card (the signal LED will flash), and with a key on the transmitter the code is sent, the LED will remain lit to signal the successful saving of th
MANUFACTURER’S DECLARATION As per Enclosure II B of Machinery Directive 98/37/CE Enclosed with the technical documentation (the original copy of the Declaration is available on request) Date of the present declaration 07/12/2001 Also, they furthermore represent and warrant that the product/s that are the subject of the present Declaration are manufactured in the respect of the following main harmonized provisions: The representatives of CAME Cancelli Automatici S.p.A.