STANDALONE MODE LOOP (Loop 1–4)
Dimmer Sets brightness 0–100
Step time Sets step time
0.1 s to 10.0 s
Fade time Sets fade time in percent 0% to 100%
Delay Delay time for slave groups 0.0 s to 2.0 s
1st step
15 colors from Color Preset Red to CW (Cold White)
4 colors from User Color User 1 to User 4
UV light UV
Blackout Blackout
2nd step " "
3rd step
15 colors from Color Preset Red to CW (Cold White)
4 colors from User Color User 1 to User 4
UV light UV
Blackout Blackout
------- Skip step
4th step " "
SLAVE MODE
Standard slave mode: Starting from the main display, press MODE to enter the main menu. Now use UP and DOWN to select the menu
item Slave, confirm with ENTER, select Slave Group 0 and again confirm with ENTER. Connect the slave and the master units (same model,
same software version) using a DMX cable, and enable one of the standalone modes on the master unit (Auto, Static, Color Preset, User
Color, Loop). The slave unit will now exactly follow the master unit.
--------Menu-------
DMX Address
DMX Mode
DMX Delay
Standalone
Slave
Settings
System Info
----Slave Group----
Standalone
Slave
Settings
Mode
Slave
0
Main display
Advanced slave mode: If, in master/slave mode, you would like to control the slave units via one of the standalone modes Auto or
Loop, the control signal can be passed on with a delay in up to 15 steps (ROOTPAR4: Slave Group 1–15, ROOTPAR6: 1–13). The delay is
defined in the submenu item Delay in the respective standalone mode and the delay factor in the slave menu of the corresponding spotlight.
This is a simple way to create a running light effect with a large number of spotlights that are all the same model and which are all
running the same software version. This is otherwise only realisable with a suitable DMX controller and time-consuming programming.
--------Menu-------
DMX Address
DMX Mode
DMX Delay
Standalone
Slave
Settings
System Info
----Slave Group----
Standalone
Slave
Settings
----Slave Group----
Standalone
Slave
Settings
Mode
Slave
Gr 1 2.0
s
CLROOTPAR4 CLROOTPAR6
1–15 1–13
Main display
with group number
and delay time in
master unit
Assign the spotlights to one of up to 15 groups as desired (ROOTPAR4: Slave Group 1-15, ROOTPAR6: 1-13). Multiple spotlights may be
assigned to a group. The group number is also the factor by which the delay time set in the master unit is multiplied (see setup example).