Instructions / Assembly
the front cover. This is the only
screw you need to remove. All
of the wiring is done with push
together plastic connectors. Make
sure that the wire terminals are
connected to the top of the battery
compartment and all other wires
are connected. (Call Technical
Support at 1.800.650.2433)
6. Debris may have entered into the
water regulator. Reverse the flow
of water by connecting the water
source to the outlet of the water
heater and run water in reverse
through the system. This back
flushing will remove the debris.
UNIT WILL NOT IGNITE
(There are audible clicks at startup
but the burner does not ignite)
1. Make sure propane tank is full and
tank is turned on.
2. Make sure there is an adequate
supply of water flowing through
the system. The appliance
requires a minimum of 1 quart of
water per minute flowing through
the system at a minimum pressure
of 25 psi before it will ignite the
burners.
3. Check gas connections for leaks
using the soapy water test. If leaks
are found make sure the problem
is resolved before attempting to
ignite the appliance. A gas leak
will cause the regulator to reduce
the gas flow. When turning on the
LP gas tank open the valve very
slowly.
4. Remove regulator hose from
fitting on appliance and ensure
there is no obstruction in the
fitting on the appliance.
UNIT IGNITES AND THEN SHUTS OFF
1. Make sure there is an adequate
supply of water flowing through
the system. The appliance
requires a minimum of 1 quart of
water per minute flowing through
the system at a minimum pressure
of 25 psi before it will ignite the
burners.
2. Excessive winds may blow the
flame out.
3. Make sure propane tank is full and
tank is turned on.
4. The ignition sensor may not be
adjusted properly. These wires
are located directly above the
burner. The wires should be bent
at 90 degrees and approximately
1/4” above the burner. Use a pair
of pliers to bend the wires as
needed.
5. The thermocouple on the heat
exchanger may need adjusted.
The thermocouple should be
centered in the hole on the heat
exchanger.
6. There may be a problem with the
thermostat. Call customer service
at 1.800.650.2433.