DIRECTION OF ROTATION
NOTE: Improper rotation will result in reduced compressor life
The direction of rotation must be counterclockwise (as shown by
the arrow on the flywheel in Figure 13) while facing the flywheel
side of the pumpThe motor nameplate will show wiring
information for counterclockwise rotation�
The proper direction is very important� The direction of rotation
of 3 phase motors can be reversed by interchanging any two
motor-line leads� For single phase motors, refer to the motor
nameplate