Troubleshooting Guide for Units in Service for a Period of Time
SYMPTOM CAUSE SOLUTION
Motor does not run Loose electrical connections The entire electrical system should be checked by a certified electrician�
The incoming wires and the compressor electrical connections should
be checked� Loose connections will cause malfunctions
Blownfuseand/ortripped
breaker
The breaker and fuses required for this unit must be time delay
A tripped breaker or blown fuse may result from a direct short to
ground, high current draw, improper wiring, incorrect fuse or breaker
size and/or type� This needs to be evaluated by a service center or
certified electrician
Starter overload tripped Check and reset if necessary� If the overload trips after the initial reset,
refer to the section of the manual that covers this issue
Defectivecapacitor Check and replace (if necessary) defective capacitor
Defectivemagneticstarter First check for any loose wiring and tighten if loose� Check and replace
(if necessary) defective magnetic starter�
Motor hums; motor
draws high amps, trips
overload, trips breaker,
or blows fuse on start up
Defectivepressureswitch
unloader
Drainthetankofallpressure.Restartcompressorundernoload.If
compressor is able to start, then the unloader needs to be checked
If this problem is not corrected it will fail the motor and / or other
electrical components�
Defectivecheckvalve-
constant loss of tank
pressure
Determineifthecheckvalveisworkingproperly-pressureswitch
unloader should quit hissing after the compressor shuts off� If the
hissing continues and if there is a constant loss of tank pressure, then
the check valve is not working properly� Replace check valve
Loose electrical connections The entire electrical system should be checked by a certified electrician�
The incoming wires and the compressor electrical connections should
be checked� Loose connections will cause malfunctions
Defectivecapacitor Check and replace (if necessary) defective capacitor
Valveproblemorblown
gasket
Check gasket and replace as needed� Other symptoms occur when a
valve is not sealing or a gasket is blown such as higher than normal amp
draw which may trip out the overload or breaker
Compressor runs but
builds pressure slowly
Air leak Check the entire system for leaks, including the compressor unit and
any piping attached to the compressor
Dirtyairfilter Air filters need to be changed regularly based on usage and
environment� A dirty filter may appear to be clean� Change filters often
Valveproblemorblown
gasket
Check gasket and replace as needed� Other symptoms occur when a
valve is not sealing or a gasket is blown such as higher than normal amp
draw which may trip out the overload or breaker
Tank cracked Replace the tank� The unit should not be run under any conditions.
Tanks cannot be welded or patched�
Interstage safety valve
pops off when the unit is
running
Malfunctioning interstage
safety valve
Valveproblemorblowngasket.Highpressureairbackflowsintothe
low pressure side of the pumpThis is caused by valve leakage or blown
gasket
Low head bolt torque Check and retighten head bolts to specified torque
Defectiveinterstagesafety
valve
Replace interstage safety valve� Under no circumstances plug the safety
valve port
Oil out breather
Worn rings or scored cylinder Replace rings and/or replace cylinder
Compressor running hot Make sure compressor is running the correct rotation� Compressor
should be clean and in a well ventilated area� Oil should be changed on
regular intervals according to the specifications listed in the manual�
Air filter must be changed as it gets dirty
Continued on next page