Manual

Appendix A. Quick Start
The quick start section describes setting up a camera to a CR800, CR850,
CR1000, or CR3000 datalogger. If using a CR10X, CR510, or CR23X, please
call the factory.
Configure the logger with Device Configuration.
1. Select the port to be used and select the baud rate to use. If using
RS232 connected to a com port, use the following for connections: pin
3 to odd # control port, pin 2 to even # control port, pin 5 to ground.
2. Select the destination address.
3. Enter the USR drive size (33 kb x num images + 66 kb). This formula
is for very high compression images.
4. Configure the files manager.
5. Help for each setting is in Device Configuration.
Configure the camera.
1. Select the Pak port to use.
2. Select the baud rate for the port used.
3. Select the compression level — very high is suggested. Help for each
setting is in Device Configuration.
Connect the camera to the CR1000 to the desired interface, and the power
cable to the CC640 Power the devices.
Place the camera switch to the “on” position.
Press the camera “snap” button. Observe that the camera light flashes a
few times, pauses then stays illuminated for about 40 seconds.
To retrieve the image use LoggerNet and connect to the logger. Select
“tools” then file control to get to the file control menu.
In the file control menu select the USR drive. Then observe the image file
name with JPG as the extension. Select the file with a left click, and
download the image to a directory that you select.
Go to Windows Explorer, find the image, and open it by double clicking
on the file name.
A-1