Appendix A. CM106B Allowable Wind
Speeds
CM106B load ratings assume:
Sensors (effective area = 1.4 ft
2
) at top of mast
Solar panel (10.5 in x 16.5 in) at mast base
Enclosure (14 in x 16 in) mounted to leg
Guy wires attached to mast at 3.8 ft above tripod body
Adequate ground anchors (stakes alone may not resist foot vertical
pullout force)
Tripod
Footprint
Dia.
Mast
Height
Mast
Config-
uration
Guy
Anchors
Max.
Allowable
Gust
Wind
Speed
Max.
Allowable
Equipment
Weight
Foot
Vertical
Pullout
Force at
Gust
Speed
Guy-
Wire
Tension
at Gust
Speed
Ideal Guy-
Wire
Installation
Pre-
Tension
ft m ft m mph m/s lb kN lb kN lb kN lb kN
11.5 3.5 7 2.1 Retracted
Unguyed 104 46 964 4.3 70 0.31 - - - -
Attached to
legs @ feet,
45deg
Zenith
159 71 639 2.8 163 0.73 300 1.3 150 0.67
Independent
anchors @
45deg
Zenith
159 71 639 2.8 56 0.25 300 1.3 150 0.67
8.7 2.7 9.3 2.8 Retracted
Unguyed 104 46 964 4.3 160 0.71 - - - -
Attached to
legs @ feet
159 71 438 1.9 352 1.57 400 1.8 200 0.89
Independent
anchors @
45deg
Zenith
159 71 639 2.8 155 0.69 300 1.3 150 0.67
11.5 3.5 10 3.0 Extended
Unguyed 81 36 964 4.3 59 0.26 - - - -
Attached to
legs @ feet,
45deg
Zenith
132 59 544 2.4 157 0.70 400 1.8 200 0.89
Independent
anchors @
45deg
Zenith
132 59 544 2.4 17 0.08 400 1.8 200 0.89
A-1