Model CS205 10-Hour Fuel Temperature Stick Revision: 5/08 C o p y r i g h t © 1 9 9 8 - 2 0 0 8 C a m p b e l l S c i e n t i f i c , I n c .
Warranty and Assistance The MODEL CS205 10-HOUR FUEL TEMPERATURE STICK is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective products.
CS205 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. General Description.....................................................1 2. Specifications ..............................................................1 3. Installation....................................................................1 4. Wiring............................................................................2 5.
Model CS205 10-hour Fuel Temperature Stick 1. General Description The CS205 Temperature Stick is a Ponderosa pine dowel 4.5 inches long and 0.5 inches in diameter. The dowel is fabricated to USFS specifications, to be used as a fuel moisture sensor. Campbell Scientific, Inc. has bored a hole and cut a split into one end of the dowel. A model 107 Temperature Probe is inserted into the CS205 to measure fuel temperature.
Model CS205 10-hour Fuel Temperature Stick FIGURE 3-2. CS205 Mounts on the Mounting Stake with the CS505 4. Wiring Connections to Campbell Scientific dataloggers are given in Table 4-1. Temperature is measured with one Single-Ended input channel and an Excitation channel. TABLE 4-1.
Model CS205 10-hour Fuel Temperature Stick 5. Datalogger Programming This section is for users who write their own datalogger programs. A datalogger program to measure this sensor can be created using Campbell Scientific’s Short Cut Program Builder software. You do not need to read this section to use Short Cut. The Temp107 measurement instruction (P11), is used with dataloggers that are programmed with Edlog (e.g. CR10X, CR23X) to measure the 107 probe.
Model CS205 10-hour Fuel Temperature Stick 5.2 CR10X Programming ;{CR10X} *Table 1 Program 01: 10 Execution Interval (seconds) 1: Temp (107) (P11) 1: 1 Reps 2: 1 SE Channel 3: 21 Excite all reps w/E1, 60Hz, 10ms delay 4: 1 Loc [ T107_C ] 5: 1.0 Multiplier 6: 0.
This is a blank page.
Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbellsci.com Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za cleroux@csafrica.co.za Campbell Scientific Australia Pty. Ltd. (CSA) PO Box 444 Thuringowa Central QLD 4812 AUSTRALIA www.campbellsci.com.au info@campbellsci.com.au Campbell Scientific do Brazil Ltda.