TABLE 8-4 shows an example of checking the CRC. 
TABLE 8-4. Checking CRC Example 
Initial Command  Response 
0V! 
Where 0 is the sensor’s address. 
00013<cr><If> 
Where (from left to right), 
0—sensor’s address; 
001—the amount of time (in seconds) that 
you must wait before sending the send data 
command; 
3—the number of values that will be 
placed in the buffer. 
Subsequent Command  Response 
0D0! 
Where the first zero is the 
sensor’s address. 
0+0+1610000+3320000<cr><If> 
Where (from left to right), 
0—sensor’s address; 
0—CRC check (0 = OK); 
1610000—adapter version (1.61.00.00); 
3320000—sensor version (3.32.00.00). 
8.1.5  Get Units 
Use the aXGU! command to get the current units setting of the sensor. If the 
units are feet, a 1 will be returned, and if the units are meters, a 0 will be 
returned. 
8.1.6  Get Water Conditions 
The aXGWC! command returns the current setting of the water conditions. 
Possible water conditions are: 
1 = smooth (default) 
2 = medium 
3 = rough 
0 = undefined (custom settings) 
8.1.7  Get Power Operation Mode 
The 0XGPOM! command provides the current power operation mode setting 
of the sensor. 