Owner manual
CS506 Fuel Moisture Sensor
5.2 CR10X Programming
The following program measures a CS506 fuel moisture sensor using Edlog’s
Instruction 27 (Period Averaging). See Table 5-1 for wiring details that match
this program.
;{CR10X}
;CR10X Program for CS506
*Table 1 Program
01: 10.0000 Execution Interval (seconds)
1: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 30 Then Do
2: Do (P86)
1: 41 Set Port 1 High
3: Period Average (SE) (P27)
1: 1 Reps
2: 4 200 kHz Max Freq @ 2 V Peak to Peak, Period Output
3: 1 SE Channel
4: 100 No. of Cycles
5: 1 Timeout (0.01 sec units)
6: 1 Loc [ PA_uS ]
7: 1 Multiplier
8: 0 Offset
4: Do (P86)
1: 51 Set Port 1 Low
5: If (X<=>F) (P89)
1: 1 X Loc [ PA_uS ]
2: 4 <
3: 17.701 F
4: 30 Then Do
6: Polynomial (P55)
1: 1 Reps
2: 1 X Loc [ PA_uS ]
3: 2 F(X) Loc [ FuelM ]
4: -130.09 C0
5: 7.6298 C1
6: 0.0 C2
7: 0.0 C3
8: 0.0 C4
9: 0.0 C5
7: Else (P94)
7