CS705 Snowfall Adapter Revision: 5/13 C o p y r i g h t © 1 9 9 7 - 2 0 1 3 C a m p b e l l S c i e n t i f i c , I n c .
Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless otherwise specified in the corresponding Campbell pricelist or product manual. Products not manufactured, but that are re-sold by Campbell, are warranted only to the limits extended by the original manufacturer.
Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing in countries served by Campbell Scientific, Inc. directly. Affiliate companies handle repairs for customers within their territories. Please visit www.campbellsci.com to determine which Campbell Scientific company serves your country. To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 227-9000.
Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to specific sections. 1. Introduction .................................................................1 2. Cautionary Statements...............................................1 3. Initial Inspection .........................................................2 3.1 Ships With............................................................................................2 4.
Table of Contents ii
CS705 Snowfall Adapter 1. Introduction The CS705 Snowfall Adapter converts a TE525WS Texas Electronics Rain Gage to a rain and snow gage. It consists of an antifreeze reservoir, overflow tube, and catch tube. Snow captured in the catch tube dissolves into the antifreeze raising the overall level. The mixture flows through the overflow tube into the tipping bucket where it is measured. A slot in the top of the overflow tube prevents the tube from developing a siphon.
CS705 Snowfall Adapter 3. Initial Inspection 3.1 • Upon receipt of the CS705, inspect the packaging and contents for damage. File damage claims with the shipping company. • Immediately check package contents against the shipping documentation (see Section 3.1, Ships With). Contact Campbell Scientific about any discrepancies. Ships With The CS705 is shipped with the CM270, CS705 Mounting Kit (pn 20621). Refer to FIGURE 4-1 for information on positioning the various mounting hardware.
CS705 Snowfall Adapter Band Clamp (pn 20605) Catch Tube Band Clamp (pn 20606) Storage Mount (pn 20636) Antifreeze Reservoir TE525WS (purchased separately) Funnel (pn 14087) 0.5 in O.D. Stub (connect hose here) U-bolt Bracket (pn 20638) Flat Washers (pn 4365) Lock Washers (pn 4366) Nuts (pn 18126) U-bolt (pn 17492) FIGURE 4-1. CS705 mounted to pole using the CM270 Mounting Kit 1. Install the mounting pole. 2.
CS705 Snowfall Adapter Catch Tube (pn 13641) Band (pn 10786) Overflow Tube (pn 10750) Antifreeze Reservoir (pn 13645) Entry Seal (pn 10785) Band (pn 12319) FIGURE 4-2. CS705 exploded view 5. CAUTION Insert the CS705 antifreeze reservoir into the rain gage funnel. Wear safety glasses during handling and pouring of antifreeze. 6. Fill the reservoir with PGE antifreeze (pn 10869) until a small amount flows out the overflow tube. The reservoir holds ≈2.5 gallons. 7.
CS705 Snowfall Adapter 11. Fasten the catch tube of the CS705 to the mounting pole using the band clamps and storage mount (see FIGURE 4-1). 12. Connect the hose to the 0.5 inch stub at the base of the funnel (see FIGURE 4-1). 13. Place the pail below the rain gage and place the other end of the hose in it. 5.
CS705 Snowfall Adapter 5.2 Tipping Bucket Compatibility The CS705 is equipped with a specially sized cylinder that allows it to nest within the 8-inch orifice of the TE525WS Texas Electronic Rain Gage. The CS705 cannot be directly used with TE525, TE525MM, CS700, or TB4 rain gages. However, the TE525 and TE525MM gages can be converted to a TE525WS at Campbell Scientific. Refer to the Assistance section at the front of this manual for the steps required to return equipment to Campbell Scientific. 6.
CS705 Snowfall Adapter Gages sited improperly and subjected to high winds will under catch winter precipitation generating erroneous data. An improperly sited gage subjected to high winds can be damaged by the wind. 60 to 90 FIGURE 7-1. Proper gage siting 7.2 Mounting Pole A user-supplied mounting pole or Campbell Scientific CM300-series stainlesssteel mounting pole can be used to mount the CS705 away from the tripod or tower.
CS705 Snowfall Adapter 24” 8” FIGURE 7-2.
CS705 Snowfall Adapter 3.5” 1.5” 24” 14” FIGURE 7-3. Pedestal kit options 7.3 Datalogger Programming Refer to the manual supplied with the TE525WS Texas Electronics Rain Gage. The manual is also available at www.campbellsci.com. 8. Maintenance The CS705 requires regular site visits. The number of required visits mainly depends on snowfall. Frequent or heavy snows require more site visits.
CS705 Snowfall Adapter 1:3 are not recommended. Refer to FIGURE 8-1 to determine the amount of remaining antifreeze based on precipitation (water equivalent) recorded. 4.500 4.000 Mix Ratio (Water to Antifreeze) 3.500 3.000 2.500 2.000 1.500 1.000 0.500 0.000 0 1 2 3 4 5 6 7 8 9 10 Water Equivalent Received (inches) FIGURE 8-1. Mix ratio versus precipitation received The TE525WS rain gage is designed to discharge precipitation out its base and onto the ground.
CS705 Snowfall Adapter 9. References McCaughey, W. and Farnes, P.: 1996, “Measuring Winter Precipitation with an Antifreeze-Based Tipping Bucket System”, Proceedings 64th Western Snow Conference, 130-136. McGurk, B.J.: 1992, “Propylene Glycol and Ethanol as a Replacement Antifreeze for Precipitation Gauges: Dilution, Disposal, and Safety”, Proceedings 60th Western Snow Conference, 56-65.
CS705 Snowfall Adapter 12
Appendix A. MSDS for Campbell Scientific CS705 Antifreeze Date Printed: 09-26-1997 Interstate Chemical Co. MSDS for CAMPBELL SCIENTIFIC CS705 ANTIFREEZE Page 1 1899-- 1 — Site Specific Information Customer: 2 — Section I – General Information MANUFACTURER’S NAME: Interstate Chemical Co. EMERGENCY TELEPHONE NUMBER: (412) 981-3771 CHEMTREC EMERGENCY TELEPHONE NUMBER: (800) 424-9300 ADDRESS (NUMBER, STREET, CITY, STATE, ZIP): 2797 Freedland Rd. Hermitage, Pa.
Appendix A. MSDS for Campbell Scientific CS705 Antifreeze Date Printed: 09-26-1997 Interstate Chemical Co. MSDS for CAMPBELL SCIENTIFIC CS705 ANTIFREEZE 1899-- 4 — Section III – Physical Data BOILING POINT (INDICATE IF “F” OR “C”): 174-212 F VAPOR PRESSURE (mm Hg): 23 @ R.T. VAPOR DENSITY (AIR = 1): 2.1 SPECIFIC GRAVITY (H2O=1): 0.9164 PERCENT VOLATILE BY VOLUME (%): 100% EVAPORATION RATE (But Ac = 1): 1.7 SOLUBILITY IN WATER: Complete APPEARANCE AND ODOR: Clear, colorless, liquid; mild odor.
Appendix A. MSDS for Campbell Scientific CS705 Antifreeze Date Printed: 09-26-1997 Interstate Chemical Co. MSDS for CAMPBELL SCIENTIFIC CS705 ANTIFREEZE Page 3 1899-- 6 — Section V – Fire and Explosion Hazard Data (continued) UNUSUAL FIRE AND EXPLOSION HAZARDS: Vapors form from this product and may travel or be moved by air currents and ignited by pilot lights or other ignition sources. 7 — Section VI – Health Hazard Data THRESHOLD LIMIT VALUE: See sect. II.
Appendix A. MSDS for Campbell Scientific CS705 Antifreeze Date Printed: 09-26-1997 Interstate Chemical Co. MSDS for CAMPBELL SCIENTIFIC CS705 ANTIFREEZE Page 4 1899-- 7 — Section VI – Health Hazard Data (continued) EFFECTS OF REPEATED OVEREXPOSURE: • Long-term repeated overexposure to methanol vapor concentrations of 3000 ppm or greater may allow a cumulative effect to occur w/ resulting nausea, vomiting, headache, ringing in the ears, insomnia, trembling, unsteady gait, vertigo, clouded double vision.
Appendix A. MSDS for Campbell Scientific CS705 Antifreeze Date Printed: 09-26-1997 Interstate Chemical Co. MSDS for CAMPBELL SCIENTIFIC CS705 ANTIFREEZE Page 5 1899-- 8 — Section VII – Reactivity Data STABILITY (choose one): ( ) UNSTABLE ( x ) STABLE * CONDITIONS TO AVOID: None. INCOMPATBILITY (MATERIALS TO AVOID): Strong oxidizers, strong inorganic acids. HAZARDOUS DECOMPOSITION PRODUCTS: CO AND CO2 HAZARDOUS POLYMERIZATION (choose one): ( ) MAY OCCUR ( x ) WILL NOT OCCUR * CONDITIONS TO AVOID: None.
Appendix A. MSDS for Campbell Scientific CS705 Antifreeze Date Printed: 09-26-1997 Interstate Chemical Co. MSDS for CAMPBELL SCIENTIFIC CS705 ANTIFREEZE Page 6 1899-- 11 — Section X – Shipping Data D.O.T. SHIPPING NAME: FLAMMABLE LIQUIDS, N.O.S. (contains Ethanol) PRODUCT NAME: CAMPBELL SCIENTIFIC CS705 ANTIFREEZE D.O.T. HAZARD CLASS: 3 U.N./N.A. NUMBER: UN-1993 (PG II) PRODUCT RQ: N/A/ D.O.T. LABEL: FLAMMABLE D.O.T. SUBSIDIARY LABEL: N/A D.O.T.
Appendix A. MSDS for Campbell Scientific CS705 Antifreeze Date Printed: 09-26-1997 Interstate Chemical Co. MSDS for CAMPBELL SCIENTIFIC CS705 ANTIFREEZE Page 7 1899-- 12 — Section XI – Special Precautions (continued) TRANSFER HAZARD – Vapors of this product may be ignited by static sparks.
Appendix A.
Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbellsci.com Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za • cleroux@csafrica.co.za Campbell Scientific Australia Pty. Ltd. (CSA) PO Box 8108 Garbutt Post Shop QLD 4814 AUSTRALIA www.campbellsci.com.au • info@campbellsci.com.au Campbell Scientific do Brasil Ltda. (CSB) Rua Apinagés, nbr.