Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless otherwise specified in the corresponding Campbell pricelist or product manual. Products not manufactured, but that are re-sold by Campbell, are warranted only to the limits extended by the original manufacturer.
Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing in countries served by Campbell Scientific, Inc. directly. Affiliate companies handle repairs for customers within their territories. Please visit www.campbellsci.com to determine which Campbell Scientific company serves your country. To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 227-9000.
CVD20 Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to specific sections. 1. Introduction..................................................................1 2. Cautionary Statements................................................1 3. Initial Inspection ..........................................................1 4. Specifications ..............................................................1 5. Installation.......
CVD20 20:1 Voltage Divider 1. Introduction The CVD20 provides six single-ended or six differential channels for connecting sensors that have a higher voltage output than what a datalogger can measure. Resistors in the CVD20 divide the sensor's signal voltage by a factor of 20. 2. Cautionary Statements The CVD20 is rugged, but it should be handled as a precision scientific instrument. 3. Initial Inspection Upon receipt of the CVD20, inspect the packaging and contents for damage.
CVD20 20:1 Voltage Divider 1). A two-foot length should be sufficient if the datalogger and CVD20 are housed in the same enclosure. TABLE 1. Recommended Cables for Datalogger Connection Number of Single-ended or Differential Channels Connected Recommended Cable(s) 1 (1) CABLE2CBL-L 2 (1) CABLE4CBL-L 3 (1) CABLE2CBL-L and (1) CABLE4CBL-L 4 (2) CABLE4CBL-L 5 (1) CABLE2CBL-L and (2) CABLE4CBL-L 6 (3) CABLE4CBL-L CVD20 20:1 VOLTAGE DIVIDER DATALOGGER AG or FIGURE 1.
CVD20 20:1 Voltage Divider The multiplier to use with the voltage measurement must take into account the divisor, the calibration of the sensor, and the units desired for the result. 6.1 Examples Suppose the user wants to measure a sensor with a 0 to 5 V output. Using the CVD20 20:1 voltage divider, the 5 volt output will be divided to 5/20 = 0.25 V or 250 mV.
CVD20 20:1 Voltage Divider 4
Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbellsci.com Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za • cleroux@csafrica.co.za Campbell Scientific Australia Pty. Ltd. (CSA) PO Box 8108 Garbutt Post Shop QLD 4814 AUSTRALIA www.campbellsci.com.au • info@campbellsci.com.au Campbell Scientific do Brazil Ltda.