Instruction Manual
NR01 Four-Component Net Radiation Sensor 
; IR01_upCor = IR01_up+5.67  10-8  Temp_K4 
; IR01_dnCor = IR01_dn+5.67  10-8  Temp_K4 
12: Z=F (P30) 
 1:  5.67   F 
 2:  -8   Exponent of 10 
  3:  25    Z Loc [ scratch_1 ] 
13: Z=F (P30) 
 1:  4   F 
 2:  0   Exponent of 10 
  3:  26    Z Loc [ scratch_2 ] 
14: Z=X^Y (P47) 
  1:  6    X Loc [ Temp_K ] 
  2:  26    Y Loc [ scratch_2 ] 
  3:  27    Z Loc [ scratch_3 ] 
15: Z=X*Y (P36) 
  1:  25    X Loc [ scratch_1 ] 
  2:  27    Y Loc [ scratch_3 ] 
  3:  28    Z Loc [ scratch_4 ] 
16: Z=X+Y (P33) 
  1:  3    X Loc [ IR01_up ] 
  2:  28    Y Loc [ scratch_4 ] 
  3:  11    Z Loc [ IR01_upCor ] 
17: Z=X+Y (P33) 
  1:  4    X Loc [ IR01_dn ] 
  2:  28    Y Loc [ scratch_4 ] 
  3:  12    Z Loc [ IR01_dnCor ] 
; 
;Output data to final storage every 60 minutes 
18: If time is (P92) 
  1:  0    Minutes (Seconds --) into a 
  2:  60    Interval (same units as above) 
  3:  10    Set Output Flag High (Flag 0) 
19: Real Time (P77) 
   1:  0220    Day,Hour/Minute (midnight = 2400) 
20: Average (P71) 
 1:  12   Reps 
  2:  1    Loc [ SR01_dn ] 
Note: Proper entries will vary with program and *input channel usage. For other loggers use: 
**  25 mV range for CR10X, 50 mV for 21X and CR7 
*** 4200 mV for 21X and CR7, 2100 mV for CR10X 
30 