Software User Manual

Section 1. Setting Up the Network and Communicating
1-5
1.3.3.1 Hardware Tab
Communication Enable - Before communications can take place, all devices in
the chain must be enabled.
Maximum Time On-Line - Set to 5 min.
Maximum Packet Size - Default 2048 bytes should be used.
Extra Response Time - Default 0 ms should be used.
Maximum Baud Rate - Default of 9600.
Security Code - The CR10X-TD can have a security code to restrict access to
the system. This helps prevent inadvertent changes to the CR10X-TD’s
program or memory. Leave this value set to 0. If a security code is needed,
the CR10X-TD program must also be changed.
PakBus Address - This must correspond with the value set in the CR10X.
Default is 1. Each logger in the network must have individual numbers.
1.3.3.2 Data Collection Tab
The data collection tab is used to define what data tables will be copied from
the CR10X-TD. The tables available will not be shown until Scheduled
Collection has been enabled. Skip to the 1.3.2.3 Scheduled Collection Tab
before Data Collection Tab. Tables selected and checked with the green check
mark should only include REAL and HIST. All other tables should be marked
with the red X, excluding them from the Tables section.
All other parameters should be left as the default value.