User Manual

Appendix E. Menu System Map
WELCOME TO THE PWS100 SETUP MENU
ID {id}
SN {sn}
(0) message 0
(1) message 1
(2) message 2
(3) set time & date
(4) configuration
(5) password
(6) weather & alarm parameters
(7) terminal (any changes will be lost)
(8) info
(9) done
Make a selection: {input}
CONFIGURATION
(1) PWS100 ID
(2) TRH probe type
(3) Wetness probe type
(4) Aux probe type
(5) Hood heater temperature (C)
(6) Dew heater mode
(7) Output mode
(8) Calibration
Make selection: {input}
4
Menu operation
1..Menu will activate when terminal is open
2..Return only will go to previous menu
3..Incorrect entry will return to same menu
4..Delete will clear current entry
5..Esc will clear current entry and go back to previous menu
PWS100 Calibration
CAUTION! INCORRECT ENTRIES CAN SERIOUSLY DEGRADE ACCURACY
to edit or view instrument calibration, type 'confirm' : {input}
PWS100 View / Enter calibration disc constants
s/n 1234
velocity (m/sec) 5.000
size (mm) 2.386
visibility (mV) 0.318
enter s/n 1234 : {input}
enter size constant (mm) 2.386 : {input}
enter visibility constant (mV) 0.318 : {input}
0
PWS100 View / Adjust calibration
Latest results from calibrator date 21:05:08
latest target--range calibration date
Velocity_Centre 5.000 4.900 5.100 21:05:08
Velocity_Left 5.000 n/a n/a n/a
Velocity_Right 5.000 n/a n/a n/a
Size_Centre 2.350 2.311 2.461 21:05:08
Visibility (mV) 0.300 0.286 0.350 21:05:08
Visibility Offset (uV) 0.000 -2.000 2.000 n/a
(0) no change
(1) adjust calibration (THIS WILL TAKE IMMEDIATE EFFECT)
Make selection : {input}
Update velocity calibration y/n : {input} saved
Update size calibration y/n : {input} saved
Update visibility calibration y/n : {input} saved
1
8
E-3