Instruction manual

CC5MPX Digital Camera
10
4. Cables/Wiring
4.1 Power & I/O Cable Connections
The wiring for the Power & I/O Cable connector assemble is as shown in Table 4-
1. The wires can be terminated directly on the control ports of a compatible
datalogger.
It is essential that the Ground cable be connected first when wiring the
camera to the datalogger or the power supply
Table 4-1 Power & I/O Cable Color Connections
Color
Function Connection
Black
Power Ground
System Ground
Red
Input Power
Power Source 9
-30 VDC
Green
RS
-
232 TX (output)
RS
-
232 Input (RX control port of datalogger
or Pin 2 of a computer (DTE) DB
-9
Connector)
RS
-485A when configured to RS-485
White
RS
-232 RX (input)
RS
-232 Output (TX control port of a
datalogger or Pin 3 of a computer (DTE)
DB
-9 connector)
R
S-485B when configured to RS-485
Yellow
Communication
Switched Power
(Output)
This line is intended to power a
communication device. The camera
switches the Input power voltage to this line
Blue
External Trigger
(Input)
Connect to external signal source (i.e.
datalogger
control port). The external signal
wakes up or initiates image/video
acquisition
Clear
Shield
Shield/Earth Ground
Refer to Section 8, Internal Jumpers if the current RS-232 or RS-485 interface
option needs to be changed in the camera.