7.4.5.4 Heater Power Control
The Heater Power Control setting controls the operation of the optional window
defroster. If enabled, the camera will only turn on the heater if the current internal
temperature is below the threshold setting. The temperature threshold values are
limited to -40°C to +25°C.
If the Always On option is selected, the heater will be on whenever the temperature
is below the threshold and the camera is not in a low powered state.
If Minutes prior to schedule is selected, the camera will wake up prior to any of the
Self-Times schedules and turn on the heater if the temperature is below the
threshold settings. This feature does not work with motion detection or external
trigger modes.
This is useful for a remote site that may be prone to riming and frost. A camera that
is setup to take hourly pictures can be configured to turn on the defroster several
minutes prior to the scheduled picture to defrost the window.
7.4.6 Update
The Update I/O submenu (see Figure 7-17) provides the ability to update the
firmware in the camera. It is recommended to check for firmware updates on the
Campbell Scientific website to ensure that the camera has the most recent version
of firmware.
Once a file is downloaded, click on the Browse button to select the new firmware
update with the ‘tar.gz’ file extension. Once the proper file is selected, click on the
Update button and the process will begin.
During the update process DO NOT disconnect power,
close web browser, or navigate away from the Update
page. DO NOT extract the firmware update from the
.tar.gz file. This compressed file must be sent to the
CC5MPX in order to update the firmware.
Once the firmware update process is completed a webpage will be displayed
indicating that the process has completed. The camera will reboot itself. It will take
a few minutes for the camera to operate as normally.
The firmware update process normally keeps all configuration settings in the
camera. It is recommended to verify the settings after an update.
Figure 7-17 Update Menu