Specifications

CC640 Digital Camera
*D 13:00
15A 15:???? – PakBus Address (prefer 1) must match the destination
PakBus address of the camera setting.
A 01:0000 –The Max number of Nodes recommend 3 or more
A 02:0000 –The Max number of neighbours recommend 3 or more.
A 03:0000 –The Max number of routers recommend 3 or more.
A 04:0000 – Default router recommend to leave at zero
12.5 CR10X Multiple Cameras
Multiple cameras can be placed on a single CR10X datalogger. However, the
system should be configured so that image transfers to the datalogger from
more than one camera do not occur at the same time. If a collision does occur,
images will not get stored onto the datalogger. Each camera attached to the
logger has to have a different PakBus, and CSDC address.
12.6 CR10X Connections
The Ext. connection is optional if the camera is set up in self-timed mode. The
CS I/O cable length between the camera and the CR10X is limited to 12 feet or
less.
Refer to 4.4 for connections to the CR10X.
13. CR1000 Interface Guide
This section contains information for interfacing the CC640 camera to the
CR1000 datalogger. The CR1000 and the CC640 both have several different
types of communication ports. This provides different interface options for the
user. This includes using the CS I/O port, the 9 Pin RS-232 Serial Port, the
control COM ports (1-4), and RS-485 if using an MD485 interface.
13.1 CR1000 Memory Setup
To facilitate the storage of images a CFM100 allows the use of a compact flash
card on the CR1000. Memory can also be allocated from the CR1000’s
internal memory to create a virtual user drive “USR:” Entering a non-zero
value for the parameter “USR: drive size” allocates internal memory for the
drive. The amount of memory required will vary depending on each
application. A good number to start with is 524288 bytes (512K bytes which is
25% of the 2M bytes available on a standard CR1000).
The following methods can be used to set the drive size of the USR:
The Device Configuration Utility program
PakBus Graph
Editing the parameter from the Status Table
The CR1000’s optional keypad and display.
29