4. Wiring 
A schematic diagram of the CMP3-L is shown in Figure 4-1. 
Red 
Blue 
Black 
White 
Black
Shield
FIGURE 4-1. CMP3-L Schematic 
When Short Cut for Windows software is used to create the datalogger 
program, the sensor should be wired to the channels shown in the wiring 
diagram created by Short Cut. 
A differential voltage measurement is recommended because it has better noise 
rejection than a single-ended measurement. If a differential channel is not 
available, a single-ended measurement can be used. 
Connections to Campbell Scientific dataloggers for a Differential measurement 
are given in Table 4-1. A user supplied jumper wire should be connected 
between the low side of the differential input and ground (AG or 
) to keep 
the signal in common mode range. 
Connections to Campbell Scientific dataloggers for a Single-Ended 
measurement are given in Table 4-2. 
TABLE 4-1. Differential Connections to Campbell Scientific Dataloggers 
Color 
Description 
CR9000(X) 
CR5000 
CR3000 
CR1000 
CR800 
CR510 
CR500 
CR10(X) 
21X 
CR7 
CR23X 
White  Signal (+)  DIFF Analog High  DIFF Analog High  DIFF Analog High 
Black  Signal (-)  *DIFF Analog Low  *DIFF Analog Low  *DIFF Analog Low 
Shield Shield 
G 
* Jumper to AG or 
 with user supplied wire. 
A CMP3-L purchased from Campbell Scientific has different 
wiring than a CMP3 purchased directly from Kipp & Zonen. 
NOTE 