Instruction manual

SECTION 3. SAMPLE 21X PROGRAM
3-5
05: Z=X*Y (P36)
1: 42 X Loc [ e ]
2: 48 Y Loc [ RH_frac ]
3: 42 Z Loc [ e ]
06: Volts (SE) (P1)
1: 2 Reps
2: 2 15 mV Slow Range
3: 11 In Chan
4: 43 Loc [ SHF#1 ]
5: 1 Mult
6: 0 Offset
;Enter multiplier for SHF#1 (mult#1).
;
07: Z=X*F (P37)
1: 43 X Loc [ SHF#1 ]
2:
mult#1
F
3: 43 Z Loc [ SHF#1 ]
;Enter multiplier for SHF#2 (mult#2).
;
08: Z=X*F (P37)
1: 44 X Loc [ SHF#2 ]
2:
mult#2
F
3: 44 Z Loc [ SHF#2 ]
09: Volt (Diff) (P2)
1: 1 Reps
2: 4 500 mV Slow Range
3: 8 In Chan
4: 45 Loc [ Rnet ]
5: 1 Mult
6: 0 Offset
10: IF (X<=>F) (P89)
1: 45 X Loc [ Rnet ]
2: 3 >=
3: 0 F
4: 30 Then Do
;Apply positive wind correction to Rnet.
;
11: Do (P86)
1: 4 Call Subroutine 4
12: Else (P94)
;Apply negative wind correction to Rnet.
;
13: Do (P86)
1: 5 Call Subroutine 5
14: End (P95)