Instruction manual

SECTION 3. SAMPLE 21X PROGRAM
3-6
15: Pulse (P3)
1: 1 Reps
2: 1 Pulse Input Chan
3: 21 Low Level AC, Output Hz
4: 49 Loc [ WndSpd ]
5: .75 Mult
6: .2 Offset
16: IF (X<=>F) (P89)
1: 49 X Loc [ WndSpd ]
2: 1 =
3: .2 F
4: 30 Then Do
17: Z=F (P30)
1: 0 F
2: 49 Z Loc [ WndSpd ]
18: End (P95)
19: AC Half Bridge (P5)
1: 1 Reps
2: 5 5000 mV Slow Range
3: 14 In Chan
4: 2 Excite all reps w/Exchan 2
5: 5000 mV Excitation
6: 50 Loc [ WndDir ]
7: 355 Mult
8: 0 Offset
20: Internal Temperature (P17)
1: 40 Loc [ RefTemp ]
21: Thermocouple Temp (DIFF) (P14)
1: 1 Reps
2: 1 5 mV Slow Range
3: 4 In Chan
4: 2 Type E (Chromel-Constantan)
5: 40 Ref Temp Loc [ RefTemp ]
6: 46 Loc [ Tsoil ]
7: 1 Mult
8: 0 Offset
;Turn on CS615 soil moisture probe
;once every half hour.
;
22: If time is (P92)
1: 14 Minutes into a
2: 30 Minute Interval
3: 14 Set Flag 4 High
23: If Flag/Port (P91)
1: 14 Do if Flag 4 is High
2: 30 Then Do