User guide

User Guide
5
The PS100 and CH100 specifications are given in Table 2, and the performance of
the battery with temperature is given in Table 3.
Table 2 Specifications
Lead-Acid Battery fitted to the PS100
Battery Type:
Float Life @ 25°C:
Shelf Life, full charge:
Dimensions (H x W x D)
PS100:
CH100:
Weight
PS100:
CH100:
Yuasa NP7-12
5 years typical
Check twice yearly
70 x 190 x 80 mm
102 x 70 x 39 mm
3.1 kg
158 g
Charger circuit (applies to CH100 too)
Charge technique:
Fixed voltage 14V nominal (varies
with temperature)
Charge Time (AC Source): 40 hr full charge, 20 hr 95% charge
(7Ah battery, longer for larger
batteries)
Maximum charger input voltage: 25V DC or 22V AC (RMS)
Maximum sustainable charge current
with unlimited current input (@ 25°C
18V input, 14V output):
1.2A typical
Maximum output current to
Terminal from battery & charger:
12V, 1.85A
Minimum voltage drop from charge
input to battery:
2.8V
Recommended minimum charge voltage: 17V at 25°C
AC-ADAPT Transformer
Input:
Isolated Output:
230V AC, 50Hz
18V AC @ 1.2A max.
AC-ADAPT2 Transformer
Input:
Isolated Output:
230V AC, 50Hz
18V AC @ 2A max.
Standalone Battery Packs typically used with CH100
Operating Temperature Range: -40 to +60°C
BP12 12 Amp hours
BP17 17 Amp hours
BP24 24 Amp hours