Specifications

RAWS-F Remote Automated Weather Station for Fire Weather
Set screw holes must be
covered with labels
FIGURE 4.5-1. Windset
4.5.1.2 Wiring, Windset (part #034B-QD)
The windset sensor is connected to the RAWS connector panel “WS/WD”
connector COLOR CODED RED. The wind speed probe is internally wired
from the RAWS connector panel to the CR1000 datalogger.
Connector Panel “WS/WD” connector COLOR CODED RED
Connector Pin A Sensor ground to CR1000 AG
Connector Pin B Wind dir. Excitation to CR1000 Ex2
Connector Pin C Wind dir. Signal to CR1000 2H
Connector Pin D Power ground to CR1000 Ground
Connector Pin E +12V power to CR1000 +12V
Connector Pin F Wind speed signal to CR1000 P1
4.5.1.3 Maintenance, Windset (part #034B-QD)
The wind vane tail must be attached to the hub. Maintain the tail assembly
with the tail vertical. Extra labels are included with the 034B-QD to recover
the holes if the sensor has to be disassembled for maintenance. The set screw
holes must be covered with these labels to prevent corrosion and assure the
warranty. Verify free movement of the cup anemometer and wind vane.
12