Use and Care Guide

www.camplux.com
18
Visit Us: Camplux.com
support@camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
Leak testing
WARNING:
Never use an open flame to test for gas leaks, as property
damage, personal injury, or death could result.
The water heater and its gas connections must be leak tested at normal operating
pressures before it is placed in operation.
Turn on the gas shut-off valve(s) to the water heater.
Use a commercial leak detector or soapy water solution to test for leaks at all
connections and fittings. Bubbles indicate a gas leak that must be corrected.
The factory connections should also be leak tested after the water heater is
placed in operation.
High altitude
The Gas Water Heaters have been tested for use at elevations up to 2,000 feet.
Installation and use of the Gas Tankless Water Heaters above 2,000 feet may
effect overall product efficiency and performance. Installation and use of the Gas
Tankless Water Heaters above 5,000 feet is not recommended.
Installing the water heater
Flue terminal location
The location of the vent terminal depends on the following minimum clearances
and considerations (see illustration):
Additional Considerations