Installation Instructions
1.
Set fixture over the post and mark the location of the three
mounting holes on the post. Drill the three holes in the post
using a drill bit.
2.
Connect the ground wire from the fixture to the supply
ground. Attach the black wire from the fixture to the black wire of
the supply wire, then white wire to white wire using marrets.
3.
Tuck the wires into the post. Align the holes on the fixture with
the holes in the post and secure with three mounting screws
(not provided).
4.
Install proper bulb type and wattage (not included).
5.
Place finial and rubber gasket onto top cap and secure with
washer and nut.
6.
Position the top over the fixture and secure with two cap
nut screws.
Ground
Wire
White Wire
Black
Wire
Cap Nut Screws
Mounting
Screws
INSTALLATION:
Finial
Top Cap
Rubber
Gasket
Washer
Nut
SAFETY PRECAUTIONS:
OUTDOOR LIGHTING
1. TURN OFF ELECTRICAL POWER BEFORE STARTING INSTALLATION OF LIGHT FIXTURE.
2. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION
CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND
THE HAZARDS INVOLVED.
NOTE: PRODUCT MAY NOT LOOK EXACTLY AS SHOWN IN FIGURES.
QUESTIONS OR CONCERNS CONTACT CANARM AT:
1-800-265-1833 (English) / 1-800-567-2513 (French)
Monday through Friday 8:00 AM to 5:00 PM E.S.T.
L
I
G
H
T
I
N
G
&
F
A
N
S
E
C
L
A
I
R
A
G
E
S
&
V
E
N
T
I
L
A
T
E
U
R
S
!
“INSTRUCTIONS PERTAINING TO RISK OF FIRE OR INJURY TO PERSONS”
“READ ALL INSTRUCTIONS”
“IMPORTANT SAFETY
INSTRUCTIONS”
“SAVE THESE INSTRUCTIONS”
TOOLS AND MATERIALS REQUIRED:
Phillips
Screwdriver
Wire Cutters
Pliers Wrench
Wiring supplies
as required by
the Canadian
Electrical Code
and/or the
Quebec
Electrical code
O-11
08/12
Imported By: CANARM LTD., 2157 Parkedale Ave., Brockville, Ontario, K6V 5V6, Tel: (613) 342-5424, Fax: (800) 263-4598