Chapter 4: Programming your SEC-HD Phason
36
1. Press Program until the program you want to adjust displays, for
example
A pr
for program A.
2. Press Select.
The display shows
Œ 0
, the first item in the Program menu.
3. Press Down until the setting you want to adjust displays, for
example
Œ 15
for
High temperature alarm, and then press Select.
The display shows the current setting.
4. Press Up or Down to adjust the setting and then press Select.
The control returns to the Program menu.
5. Repeat steps 3 to 4 for each setting you want to adjust.
6. To return to the Main menu, press Back once. To return to the
Main display, press Back twice.
To enable or disable alarms
When you enable or disable an alarm, you do it for all programs and stages.
1. Press Program until
A L e n
displays and then press Select.
The display shows
3 0
, the first item in the Alarm enable menu.
2. To enable or disable the
High temperature alarm, press Select.
The display shows the current configuration.
Press Up or Down to toggle between
no
(not enabled) and
yes
(enabled), and then press Select.
The control returns to the Alarm enable menu.
3. To enable or disable the
Low temperature alarm, press Up or Down
until
31
displays and then press Select.
The display shows the current configuration.
Press Up or Down to toggle between
no
and
y e s
, and then press
Select.
The control returns to the Alarm enable menu.
4. To enable or disable the
Probe damage alarm, press Up or Down
until
32
displays and then press Select.
The display shows the current configuration.
Press Up or Down to toggle between
no
and
y e s
, and then press
Select.
The control returns to the Alarm enable menu.