User manual

SEC-HD user manual Monitoring your SEC-HD
39
Selecting the operating program
The SEC-HD has four configurable programs,
A, B, C, D, E, F,
and
G
if you are running a
livestock or poultry operation, you might use different programs for different stages of
development. Another option is to use different programs for different seasons.
The default operating program is
program A
. Any of the seven programs can be the operating
program. For a list of the factory defaults for the programs, see the table starting on page 54.
To select the operating program
1. Press Program until one of the seven Program settings menus
displays, for example
A pr
for program A.
At this point, it does
not matter which program menu you select.
2. Press Select.
The display shows
Œ 0
, the first item in the Program menu.
3. Press Select.
The display shows the current operating program.
4. Press Up or Down to change the operating program and then press
Select.
The control returns to the Program menu.
5. To return to the Main menu, press Back once. To return to the
Main display, press Back twice.
Acknowledging alarms
The alarm relay activates if an enabled alarm condition is present for longer than the minimum
duration of one minute. The one-minute minimum duration prevents alarms from occurring when
the temperature rises or drops for just a few seconds.
The exception to the one-minute minimum is the
power fail
alarm. The power fail alarm
automatically triggers the relay on a loss of power.
When an alarm occurs, the alarm relay activates, the LED for ALARM switches on, and the alarm
message displays. If there is more than one message, after acknowledging the first alarm, the next
one displays.
For example, if you have a high temperature and probe damage alarm, the display shows
X - AL
.
After acknowledging the high temperature alarm, the display shows
pbad
. When all alarms have
been acknowledged, the display shows the temperature.
A pr
Œ 0
’roa