User manual
Appendixes Phason
54
Appendix C: Factory defaults
When your SEC-HD leaves the factory, it comes with default settings and configuration.
Configuring and programming your SEC-HD changes the factory defaults.
Resetting your SEC-HD erases all the configuration and settings you programmed and then restores
the factory defaults. For more information, read Restoring the factory defaults, parameter 27 on
page 43.
Parameter
Default
Range/options
A
B
C
D
E, F, G
1
Group set point (°F/°C)
85.0
80.0
75.0
70.0
65.0
-13.0 to 125 °F (-25 to 51.7°C)
2
Stage 1 idle speed (%)
20
20
30
30
20
0 to 100 %
3
Stage 1 idle range (°F/°C)
80.0
75.0
70.0
65.0
60.0
-13.0 to 125 °F (-25 to 51.7°C)
4
Stage 1 set point (°F/°C)
85.0
80.0
75.0
70.0
65.0
-13.0 to 125 °F (-25 to 51.7°C)
5
Stage 1 differential (°F/°C)
86.5
82.0
77.0
73.0
68.0
-13.0 to 125 °F (-25 to 51.7°C)
6
Stage 2 idle speed (%)
20
20
30
30
20
0 to 100 %
7
Stage 2 idle range (°F/°C)
87.0
82.0
77.5
73.0
68.0
-13.0 to 125 °F (-25 to 51.7°C)
8
Stage 2 set point (°F/°C)
87.0
82.0
77.5
73.0
68.0
-13.0 to 125 °F (-25 to 51.7°C)
9
Stage 2 differential (°F/°C)
88.5
84.0
79.5
76.0
71.0
-13.0 to 125 °F (-25 to 51.7°C)
10
Stage 3 set point (°F/°C)
89.0
85.0
80.0
77.0
72.0
-13.0 to 125 °F (-25 to 51.7°C)
11
Stage 4 set point (°F/°C)
91.0
87.0
82.0
79.0
74.0
-13.0 to 125 °F (-25 to 51.7°C)
12
Stage 5 set point (°F/°C)
84.0
79.0
74.0
69.0
64.0
-13.0 to 125 °F (-25 to 51.7°C)
13
Stage 5 P-band temperature (°F/°C)
2.0
2.0
2.0
2.0
2
1 to 16.0°F (0.6 to 8.9°C)
14
Stage 5 P-band interval (minutes)
10
10
10
10
10
5 to 25 minutes
15
High temperature alarm (°F/°C)
95.0
90.0
90.0
85.0
85.0
-13.0 to 125 °F (-25 to 51.7°C)
16
Low temperature alarm (°F/°C)
80.0
75.0
70.0
65.0
65.0
-13.0 to 125 °F (-25 to 51.7°C)
17
Temperature unit
°F
°F/°C
18
Frequency
60
50/60 Hz
19
Stage 1 configuration
CL 1
OFF/CL 1 to CL 4
20
Stage 2 configuration
CL 1
OFF/CL 1 to CL 4
21
Stage 3 configuration
COOL
OFF/ON/COOL/ HEAT
22
Stage 4 configuration
COOL
OFF/ON/COOL/ HEAT
23
Stage 5 configuration
HEAT
OFF/ON/COOL/HEAT/P-COOL/P-HEAT
24
Hysteresis (°F/°C)
0.5
0.3 to 5.0°F (0.2 to 2.8°C)
30
High temperature enable
YES
NO/YES
31
Low temperature enable
YES
NO/YES
32
Probe damage enable
YES
NO/YES
33
Actuator jam enable
YES
NO/YES