WALL MOUNT FANS
8" 13 1/4" 11" 4" 12" 10 3/4" 2
10" 15 1/4" 11" 4" 14" 12 3/4" 2
12" 17 1/4" 17" 6" 16" 14 3/4" 3
14" 19 1/4" 17" 6" 18" 16 3/4" 3
16" 21 1/4" 17" 6" 20" 18 3/4" 4
18" 23 1/4" 15" 6" 22" 20 3/4" 4
20" 25 1/4" 18" 6" 24" 22 3/4" 5
24" 29 1/4" 18" 6" 28" 26 3/4" 5
30" 35 1/4" 19" 6" 34" 32 3/4" 16
36" 41 1/4" 18" 6" 40" 38 3/4" 20
42" 47 1/4" 18" 6 3/4" 46" 44 3/4" 24
D (c/c) EN
FAN
SIZE
A X A
SQUARE
BC
DIMENSIONS
Canarm/LFI’s standard fans follow a tradition of quality in design, materials and construction. All our
standard fans are developed to be efficient and economically priced. Fans are available in single, two
and variable speed models. All variable speed standard fans use an energy efficient variable speed,
dual voltage motor and blade combination.
0.00" 0.10" 0.125" 0.25"
S8-B2 Two 8" 1600/1300 1/20 115 1.7 12 48 360/300 270/150 230/110 0 11" X 11"
S10-B2 Two 10" 1600/1300 1/20 115 1.7 13 56 690/580 590/460 570/390 0 13" X 13"
S12-E1 Single 12" 1625 1/4 115 1.8 28 63 1640 1540 1510 1390 15" X 15"
S12-E2 Two 12" 1725/1140 1/4 115 3.4 32 64 1650/1090 1550/950 1520/930 1390/0 15" X 15"
S12-EVD Variable 12" 1700 1/3 115/230 5.0/2.5 32 60 1650 1540 1510 1390 15" X 15"
S14-E1 Single 14" 1625 1/4 115 1.8 30 67 2170 2070 2030 1860 17" X 17"
S14-E2 Two 14" 1725/1140 1/4 115 3.4 34 65 2180/1350 2080/1190 2060/1160 1890/0 17" X 17"
S16-E1 Single 16" 1625 1/4 115 1.8 33 68 2370 2270 2210 2060 19" X 19"
S16-E2 Two 16" 1725/1140 1/4 115 3.4 36 69 2380/1640 2280/1490 2230/1430 2070/0 19" X 19"
S16-EVD Variable 16" 1700 1/3 115/230 5.0/2.5 36 63 2370 2270 2210 2063 19" X 19"
S18-F1 Single 18" 1625 1/3 115 4.0 37 73 3200 3090 3040 2920 21" X 21"
S18-F2 Two 18" 1725/1140 1/3 115 5.3/2.9 43 74 3200/2100 3090/1890 3040/1820 2920/0 21" X 21"
S18-FVD Variable 18" 1700 1/3 115/230 3.8/1.9 45 74 3150 3050 2980 2860 21" X 21"
S20-F1 Single 20" 1625 1/3 115 4.0 41 77 3420 3220 3170 2920 23" X 23"
S20-F2 Two 20" 1725/1140 1/3 115 5.3/2.9 45 77 3440/2300 3240/2000 3180/1950 2930/0 23" X 23"
SD24-F1 Single 24" 1100 1/3 115 5.4 46 70 5000 4500 4300 3600 27" X 27"
SD24-GVD Variable 24" 1100 1/3 115/230 4.4/2.2 56 72 5050 4910 4810 4400 27" X 27"
SD30-G1D Single 30" 1100 1/3 115/230 4.4/2.2 72 82 8000 7000 6000 5000 33" X 33"
SD36-G1D Single 36" 850 1/2 115/230 6.6/3.3 88 72 10000 8500 8000 6200 39" X 39"
SD42-H1D Single 42" 850 1 230 5.5 122 83 14900 13550 13210 10800 45" X 45"
AMPS
(FLA)
WEIGHT
(LBS)
dB(A)
@5 ft
MODEL SPEED
BLADE
DIAMETER
RPM HP VOLTAGE
CFM @ STATIC PRESSURE
FRAMING
DIMENSIONS
SPECIFICATIONS
SD - STANDARD WALL EXHAUST FANS
Efficient, low maintenance and easy to install.
For a complete listing on all available accessories, see page C15.
For a complete listing of all available hoods, see page C11.
For all available control options, see Controls & Thermostats tab.
NOTE: RPM Min (Minimum) is determined when louvres are opened one inch.
Note: Wind has a significant effect on exhaust fans. A 10 mph wind creates a 0.05” pressure against the fan. A 20 mph wind
creates 0.20” pressure and 30 mph a 0.45” pressure. These pressures are in addition to the static pressure in the building. Wind
blocks or hoods should be included in all designs where fans will be subjected to winds above 10 mph.
A
A
4 Mounting Holes
.375” Diameter
Serial Model & Label
Propeller
E
SQR
C
Motor
B
314:;*78
D
D
FEATURES
Available in 8” to 42” sizes.
Single, two and variable speed models
are available.
All fans use a totally enclosed, thermally
protected motor.
The rugged steel welded box housing
has a durable powder coated finish.
Aluminum louver shutters are supported
by long life nylon bushings
(30”, 36” & 42” have PVC louvers).
8” - 24” models have heavy wire chrome
plated OSHA guards on intake side of fan.
30”, 36” & 42” models have grey powder
coated guards.
All fans are shipped completely assembled.
To determine the proper Canarm/LFI fan for your applications, use the following formula.
Number of cubic feet in room / Number of minutes per air change = Required C.F.M. Capacity
EXAMPLE: A general office, (see chart) which requires an air change every ten minutes, would
require the following fan capacity.
If office is 100’ x 40’ x 10’ = 40,000 cubic ft; 40,000 cubic ft / 10 minutes per air change =
4000 Required C.F.M.
From the chart, you would select a fan that is rated at 4000 C.F.M. at 1/8” S.P. (Static Pressure)
Assembly Hall 7 Church 15
Foundry 4
Pressing Room
1
Attic2Classroom 6 Garage
5
Projection Booth
2
Auditorium 10 Dance Hall 5 General Office
10
Summer Cooling
1
Barber Shop 6 Department Store 6 Gymnasium
8
Toilet
3
Basement 8 Dry Cleaning 5 Laundry
2 Transformer Room
1
Battery R
oom 4
Engine Room 6
Locker Room
3
Warehouse
12
Boiler Room 1 Factory 6 Machine Shop
8
Welding Shop
2
Bowling Alley 5 Forge Room 3 Plating Room
3
Application
Minutes per
Air Change
Application
Minutes per
Air Change
Application Application
Mi
nutes per
Air Change
Minutes per
Air Change
ACCESSORIES
Grey plastic weather hood
Galvanized metal hood
MC type & wet locations controls.
BACK VIEW
30”, 36” & 42”
MODELS WITH
PVC LOUVERS

Summary of content (1 pages)