5.4.1.1. Removal of a Repeater-PC or Secondary-Repeater Module
Follow the steps in section
5.3 above to switch off and remove either a Secondary-Repeater or
Repeater-PC module.
All Repeater modules between the computer and the Repeater that has been removed will
remain in the network, and their Blue “Link” status LEDs will stay on. All Repeater modules after
this point, along with the Supervisor, will become disconnected and their “Link” status LEDs will
turn off.
5.4.1.2. Insertion of a Repeater-PC or Secondary-Repeater Module
Follow the steps in section
5.3 above to install a new Secondary-Repeater module.
The Blue “Link” status LED of the newly installed Secondary-Repeater module will turn on to
indicate when it has been successfully synchronized and linked to the network.
If any downstream Repeaters and the Supervisor had been previously disconnected, their Blue
“Link” status LEDs will turn back on once the have automatically reconnected to the network.
5.4.2. Installing or Removing Supervisor Modules
In a system containing only a Supervisor-PC module, it is not possible to insert additional Repeater
modules once the system is in operation without restarting and reconfiguring the system to some
extent. In this case, proper functionality of the system requires the system operating data and CSP-
COM communication table stored in the Supervisor to be reset. This occurs whenever the serial data
cable is disconnected from the Supervisor-PC, and the role of the module changes from Supervisor-PC
to standalone Supervisor.
5.4.2.1. Removal of a Supervisor-PC or Supervisor Module
Follow the steps in section
5.3 above to switch off and remove either a Supervisor-PC or
Supervisor module.
Any Repeater modules in the system will remain connected in the network, and their Blue “Link”
status LEDs will stay on. The Supervisor however will become disconnected from the network
once it has been switched off, and all system data in the Supervisor will be lost.
PC Supervisor-PC CSP-COM