Cooker Hood Instruction Manual 1
Content 1…………………………………..………………………………Safety instructions 2…………………………………..………………………………Installation 3…………………………………..………………………………Start using your cooker hood 4…………………………………..………………………………Troubleshooting 5…………………………………..………………………………Maintenance and cleaning 6…………………………………..
SAFETY INSTRUCTIONS This manual explains the proper installation and use of your cooker hood, please read it carefully before using even if you are familiar with the product. The manual should be kept in a safe place for future reference. Never to do: Always to do: ● Do not try to use the cooker hood without the grease filters or if the filters are excessively greasy! ●Do not install above a cooker with a high level grill.
Always to do: Always to do: ●Always put lids on pots and pans when cooking on a gas cooker. ●When in extraction mode, air in the room is being removed by the cooker hood. Please make sure that proper ventilation measures are being observed. The cooker hood removes odours from room but not steam. ●Cooker hood is for domestic use only. ● Caution: The appliance and its accessible parts can become hot during operation. Be careful to avoid touching the heating elements.
INSTALLATION (VENT OUTSIDE) If you have an outlet to the outside, your cooker hood can be connected as below picture by means of an extraction duct (enamel, aluminum, flexible pipe or inflammable material with an interior diameter of 120/150mm) 1. Before installation, turn the unit off and unplug it from the outlet. 2. The cooker hoods should be placed at a distance of 65-75cm from the cooking surface for best effect. See Pic 1 3.
Pic 2 Method B See Pic3: 1. Drill 4 holes of Ø 6mm at the bottom of the hanging cupboard. 2. Put the one way valve on the air outlet of cooker hood, then install the cooker hood on the bottom of the cupboard, tighten the cooker hood with enclosed 4 screws. 3. Install the adjusted board on the bottom of the hood in order to keep out the gap between hood back and cupboard. Noice: There are 2 methods for ventilation, including ' horizontal ventilation' and ' vertical ventilation'.
Air ventilation setting Outdoor air ventilation: Turn the adjuster to outdoor position(pic.5A), install the outlet, turn on the cooker hood, then the air will be vented from the outside outlet. Indoor air ventilation: Turn the adjuster to indoor position (pic.5B), install the outlet cover, turn on the cooker hood, then the air can be vented from the inside outlet. WARNING: ➢ For safety reason, please use only the same size of fixing or mounting screw which are recommended in this instruction manual.
e. Press the button “Light”, both lights start shining .Press the button again; the lights are switched off then. TROUBLESHOOTING Fault Light on, but motor does not work Light does not work, motor does not work Oil leakage Lights not working Insufficient suction The Cooker hood inclines Possible Cause Solution Fan switch turned off Select a fan switch position. Fan switch failed Contact service center. Motor failed Contact service center. House fuses blown Reset/Replace fuses.
MAINTENANCE AND CLEANING Caution: • Before maintenance or cleaning is carried out, the cooker hood should be disconnected from the main power supply. Ensure that the cooker hood is switched off at the wall socket and the plug removed. • External surfaces are susceptible to scratches and abrasions, so please follow the cleaning instructions to ensure the best possible result is achieved without damage. GENERAL Cleaning and maintenance should be carried out with the appliance cold especially when cleaning.
INSTALLING GREASE MESH FILTERS • To install filters for the following four steps . - Angle the filter into slots at the back of the hood. - Push the button on handle of the filter. - Release the handle once the filter fits into a resting position. - Repeat to install all filters. CARBON FILTER Activated carbon filter can be used to trap odors. Normally the activated carbon filter should be changed at three or six months according to your cooking habit.
Changing the light Use the screw driver loosen the ST4*8MM self tapping screw (2pcs) from the lighting panel, take out the lighting fixture. Open the terminal box that connected with the wire, disconnect the wire connector and replace the lamp. • ILCOS D code for this lamp is: DBS-2.5/65-H-120/33 – LED modules –rectangle lamp – Max wattage: 2.
Do not dismantle the appliance in a way which is not shown in the user manual. The appliance could not be dismantled by user. At the end of life, the appliance should not be disposed of with household waste. Check with you Local Authority or retainer for recycling advice.