User Manual

Description of the Appliances
The ranges of hotplates, which can be used built-in, are supplied with two or three burners with
glass panel. All of the burners are manufactured by HORISUN. Each burner, which is operated
by a FSD/plug type gas valve, is controlled by metal control knobs positioned on the top of the
panel, each burner incorporates a flame supervision device(Thermocouple).The appliance
incorporated a battery supply of 1.5V that operates the ignition system.
The detailed differences between the models are listed below:
Table 1
4
The hob can also be installed above built-in ovens provided with cooling ventilation.
In the event the cooktop is installed above a built-in oven, a wood panel must be inserted as
insulation. This panel must be placed at about 50 mm from the bottom of the cooktop itself.
Important: When installing the cooktop above a built-in oven, the oven should be placed on
two wooden strips; in the case of a joining cabinet surface, remember to leave a space of at
least 45 x 560 mm at the back.
Installation of Built-In Cooktops on a CYLINDER COMPARTMENT
In the event the cooktop is installed above cylinder compartment, a wood panel must be
inserted as insulation. This panel must be placed at about 50 mm from the bottom of the
cooktop itself.
The opening of this compartment have to permit the easy introduction and removal of the
cylinder. The dimension of the opening and the inside of the compartment shall be at least
large enough to accommodate the cylinders (with regulator fitted) which are the most
commonly used in the country. The total area of the opening in the upper part shall be at least
1/100 of the floor area of the compartment. The total area of the openings of the base shall be
at least 1/50 of the floor area of the compartment. The cylinder support:
Shall have sufficient mechanical strength.
Shall not let the cylinder rest directly in the ground.
Shall not sill higher than the base on which the cylinder rests.
17