ALARMS
HOW CAN YOU STOP ITDISPLAY WHY SOUND ALARM
During the supply, whenever a lack of
inlet water or a too low pressure from
the main occur.
Allarm
Low Pressure
Filter Allarm
Anti-flooding
Allarm
Intervalli di 0,5 secondi.
The unit will not supply until the problem
that has caused the starting of the alarm
is solved. By pressing the button,
the alarm will be temporarily re-set to
allow to solve the inconvenience.
Once the supply hours set on the
display are reached.
Intervalli da 1 secondo.
This alarm warns the user that it is
necessary to replace the pre-filter. After
the filter replacement, in order not to
have the same message displayed
again, set at zero the operating hours
(see paragraph user programming).
In case the anti-flood feelers sense a
water presence.
Intervalli da 2 secondi.
The unit will not supply until the problem
that has caused the starting of the alarm
is solved. Switch the unit off and on to
reset the alarm. Such an alarm, if
leakages are not eliminated and if the
inner sensor is not carefully dried, would
not allow to start the unit.
Refrigerator
probe allarm
Boiler probe
allarm
In case the unit senses that one of the
two feelers are disconnected or in short
circuit .
Intervalli di 0,35 secondi.
By pressing a button, the acoustic alarm
as well as the message on the LCD are
re-set and the unit will not supply the
drink associated with the feeler causing
the alarm.
The alarm is automatically
disconnected when the malfunction
is eliminated.
Charge Timeout
Allarm
In case, after 180 seconds of filling,
the maximum level feeler is not
covered
Intervalli da 0,25 secondi.
MODALITÀ DUSO
STARTING
After switching the unit on by means of the switch ON/OFF (pag. 37) the following messages appear on the display:
After 3 seconds the following messages are alternatively displaied:
By pressing button "ON / OFF BOILER" the boiler heating element is activated and the following message is displayed:
The display indicates the temperature of the boiler and the temperature of the refrigerator in Celsius. In case the displayed value is not
included in the reading range, 3 lines are displayed.
Release 1.00 Good Morning
Refrigerator 10 C°
Filter Change 500 h
Boiler OFF
Filter Change 500 h
Boiler 50 C°
Filter Change 500 h
DRINK SUPPLY
The built-in system foresees 4 types of drinks, with programmable supply
(see paragraph “user programming” – pre-set value 15 seconds
per each drink):
To stop the supply, press any dosing button. During the supply, four Leds are switched on.
NOTE
DRINK
DOSING BUTTON DISPLAY
STILL WATER
In case “UV LIGHT OFF” is displayed during the
supply, this indicates an anomalous operation of
the sterilizer. In such a case, get in contact with
the technical assistance center.
Still water
UV LIGHT ON
SPARKLING WATER
Carbonated water
UV LIGHT ON
COLD WATER
Cold water
UV LIGHT ON
HOT WATER
Hot water
UV LIGHT ON
8 GB
By pressing a button, the acoustic
alarm as well as the message on the
LCD are disconnected, the unit will
not supply sparkling water.
When the unit is started again, the filling
will be enabled.
Unless otherwise stated in the column HOW CAN YOU STOP IT, the audible alarm can be switched off only by switching off the appliance.