Instruction manual
Candy Apple / Caramel Corn Stoves
ALL MODELS #2080, #2083, #4002 AND #4110
3
CAUTION
GAS MODEL SPECIAL INSTRUCTIONS
When installing your new gas Candy Apple or Caramel Corn Stove, obey local codes or, in the
absence of local codes, obey the National Fuel Gas Code, ANSI Z223.1-1992, or latest edi-
tion.
When selecting a non-combustible location for your gas candy apple stove, pay close atten-
tion to the installation clearances. These clearances are shown on the nameplate.
The appliance and its individual shutoff valve must be disconnected from the gas supply
piping during pressure testing of the system in excess of 1/2 psig (3.45 kPa).
After installation, all gas connections must be checked for leaks with a soap solution.
TYPES OF GAS
The nameplate is marked at the factory to indicate the type of gas your stove uses. If
necessary, the stove can be altered to switch fuels, but we suggest only qualified
personnel do this work.
ALTITUDE RANGE
The factory has sized the burner orifices for an elevation up to 2000 feet above sea level.
For high altitude operation, contact Gold Medal Customer Service Department.
Gas is safe when used properly, but dangerous when used
improperly. We suggest that installation be made by qualified
personnel only. Gas companies have competent service
personnel to provide safe installation.
Be sure to provide adequate air supply and adequate clearance
for air openings into the combustion chamber. Be sure to provide
adequate clearance for servicing and proper installation.
Do not use a match or a flame to check for leaks. You may cause
fire or explosion!