AsshownintheFigure2.6.2,theRS‐232signalpins,TXDandRXD,areintheRJ45‐Lconnector.Therefore,onlytheRJ45‐L
canbeusedtoconnecttowhentheRS‐232interfaceisselected
If RS‐485 interface is selected, both RJ‐45 connectors will be used
for the daisy‐chained/cascaded RS‐485 connections
shownintheFigure2.6.3.
StandardCablesavailableforRS232&485communicationforPVI3000throughPVI7500
Description PartNu mber TypicalUse Length
Cable,RS485comm.PVI3000‐7500 WIH‐020082 RS485cableforcommunicationgateways 7ft
Cable,RS485daisychainPVI3000‐
7500
WIH‐020081 RS485jumpercable, for3000‐7500inverter‐to‐
inverter
30in.
Fig2.6.3RS‐485connection
StandardEthernetpatchcablesarenotcompatiblewiththeinverters,eventhoughtheinvertersuseRJ‐45receptaclesand
requireCAT5ecable,thepinoutsarenotthesameastheEthernetstandard.
2.7 CommunicationIDadjustment
TheRS485communicationIDcanbesetbytwoways.Thefirstwayisassigntheaddressvalue(1‐254)byswitchingeachofthe
switcheson.Thesecondwayissettingbysoftware,wherealloftheswitchesmustbesettoOFF(0)orON(255)inwhichcase
theIDvaluewilldependonanEEPROMparameterwhichcanbechangedbysoftwaretoolsviacommunicationport.Whenusing
SolrenView data monitoring use an address between 1 and 16. SolrenView can automatically detect the ID# (see SolrenView
manual).EachinverterrequiresauniquenumberwhenconnectedtoasinglecommunicationDAS.
WIH‐020081
RS485Daisy
chain
Togatewayor
computer
WIH‐020082