Specifications

InstallationandOperationManual(REVH) PVI6500/PVI7500

37
4Power,GroundFault,ErrorLEDIndicatorsandLCDDisplay
Theinverteroperatesautomaticallywithouttheneedforuserinteractionormaintenance.
ThePVI65007500automaticallystartsfeedingACpowerintothegrideverymorningasthesunrises,assoonassufficientDC
voltageandPVpowerisavailable.Theinvertermicrocontrollerrunsthroughvariouschecksbeforegoingonline
withthegrid
andfeedingpowerintothegrid.
4.1Power,GroundFaultandErrorLEDIndicators
Therearethreelightem ittingdiodes(LEDs) mountedonthefrontoftheinvertertoshowtheoperating conditionoftheinverter(to
therightof theLCDdisplay).
Fig.4.1.1Power,Error,and GroundFaultIndicatorLEDsand LCDDispla y
ThegreenLED"Power"sh o ws the currentope ratin gcondition.
TheyellowLED"Error"indicateswhetherthereisaninternalorexternalfaultpresentandwhethertheACgridbackfeedhasbeen
interru pted .
TheredLED"GroundFault"showsifagroundfaultispresent.
DescriptionofLEDsymbolsusedtoindicateLEDstatusinthismanual
 LEDON
 LEDOFF
x Notrelevant/Inconsequential
LEDON0.9second/OFF0.1Second
¤LEDON0.1second/OFF0.9Second
LEDON0.25second/OFF0.25Second