Specifications
InstallationandOperationManual(REVH) PVI6500/PVI7500
42
MonitoringMode
Oncesystemcheckiscompleted,theinvertergoesintothemonitoringmode.Evenifallmeasurementsneededforgridfeeding
are in the acceptable range, the system will keep monitoring these measurements for a period of time. The following
informationtellsusersthatthesystemwillgointothegrid
feedingmodeinXXXsecondsandthenshowthemeasureddataof
theDCinputvoltagesandtheexistingvoltageandfrequencyonthegridside.
3seconds↓
3seconds↓
3seconds↓
If the DC voltagefalls under thePV start voltage, during the monitoringmode, the systemstays
in thismode andshows the
informationasfollows.ThesystemwillstillkeepmeasuringtheparametersofbothDCandACanddisplayingthemontheLCD.
3seconds↓
3seconds↓
3seconds↓
If measurements stay within acceptable range the system enters the grid feeding mode; the
LCD will show the following
informationinthegivenorderandrepeatthisuntilthesystemgoestoanotheroperatingmode.
Thefirstscreenshowsthecurrentoperationmode.
M o d e M o n i t o r i n
N e x t C o n n e c t X X X s
V
p
v XXX V
V a c X X X . X V
F a c X X . X H z
M o d e M o n i t o r i n g
L o w I n s o l a t i o n
V p v XXXV
V a c X X X . X V
F a c X X . X H z
g