Manual

TECHNICAL DATA
Gas connection Rp
1
/
2
(
1
/
2
” BSP female)
Pressure test point Front left hotplate injector
Gas rate adjustment None
Aeration adjustment None
Electrical connection Flexible cord fitted with a 3 pin 13 amp plug
230/240V a.c. 50Hz. 13A fuse.
29
HEAT
INPUT
G20 at 20mbar
G30 at 28-30mbar
G31 at 37mbar
BURNER
INJECTOR
3.7 kWGRILL 150
2.5 kWMAIN OVEN 115
1.9 kW
TOP OVEN 100
3.0 kWHOTPLATE
Front left and rear right
116
2.0 kWHOTPLATE
Front right and rear left
103
HEAT
INPUT
INJECTOR
3.4 kW (245g/h) 92
2.3 kW (165g/h) 72
1.9 kW (135g/h)
65
3.0 kW (220g/h) 86
2.0 kW (145g/h) 70
INSTALLATION INSTRUCTIONS