Operating instructions

10
1. This appliance is to be installed by an authorised service person only.
2. This appliance shall be installed in accordance with the manufacturer’s
installation instructions, local gas fitting regulations, municipal building
codes, electrical wiring regulations, and AS5601 the Australian Stand-
ard for gas installations. Refer also to AS5601 for pipe sizing tables.
3. Remove the heater from the carton and remove the three transit screws.
Check that the heater is suitable for gas available. Refer to the data
label located on fan chamber base, rear of lower front cover.
(Please dispose of packaging appropriately, keep away from children).
Clearances
4. Ensure the minimum clearances to combustible construction are main-
tained during installation, including adequate space for the proper
operation and servicing of the heater. For clearances to furniture and
curtains refer to warning on page 4.
For minimum clearances refer figures 10 and 11.
Note: Ensure that the combustion air opening under the heater
is not obstructed.
A CLEARANCE OF 50mm MUST BE MAINTAINED BETWEEN THE
REAR OF THE CABINET AND THE REAR WALL OF THE FIRE PLACE.
Fitment of cabinet depth spacer
The clearance is required for correct fluing of the appliance. If the
clearance is less than 50mm a cabinet depth spacer must be fitted. The
spacer can be ordered from the Cannon distributor. Order specifica-
tion for the spacer is ‘Fitzspacer”.
This is the requirement for installation into a masonry or brick fireplace
without flue connection.
Installation into a masonry/brick or mock fireplace.
5. Models FITZIB-SDSEB-NG & FITZIB-SDSEB-LP can be installed into a
masonry/brick fireplace or a mock fireplace. If installing into a mock
fireplace a mock fireplace installation kit MUST be used. The mock
fireplace kit can be ordered from the CANNON distributor. Order
specification for the part is ‘Mock kit”.
10
Installation instructions
11
15
13. Slide heater into the fireplace ensuring that gas inlet pipe is fed through
the hole at the rear bottom RHS of the heater. Refer figure 24 and gas
connection figure 26.
-
14. With heater in position, flanges should be hard against masonry. Se-
cure case flanges to the masonry. Refer figure 25.
15. Connect incoming gas supply pipe to regulator. For inlet position see
figure 26. Close gate over gas supply and seal around the pipe with
fibreglass insulation material. Sealing is important as it prevents leak-
age from fan chamber into chimney: also check for gas soundness.
25
26
Gas connections
24