MAKER’S WARRANTY Cannon FITZROY PROFILE FREESTANDING MODELS FITZP, FITZLP Cannon FITZROY PROFILE USER INSTRUCTIONS INSTALLATION INSTRUCTIONS Part No: F2774 Revision C SERVICE INSTRUCTIONS This heater is approved for use with Natural and Propane gases.
Notes Contents Contents 2 Warranty 3 Safety warnings 4-5 ❍ What to do if you smell gas ❍ Warnings ❍ Standards User instructions 6-8 ❍ Operating instructions ❍ Cleaning Heater specifications Installation instructions ❍ ❍ ❍ ❍ ❍ ❍ 9 10-15 Clearances Installation Gas connection Fuel bed & log installation Gas control Gas pressure point Flue installation 16-17 ❍ Flue kit Service instructions 18-19 ❍ General ❍ Access to components To replace the gas control To replace the fan To replace the electr
Notes Warranty The Cannon appliance is warranted against defects in materials and workmanship for a period of one, (1) year from its date of original purchase, for residential use in Australia. Warranty service, which includes parts and labour for the replacement or repair of defective parts, is available through Cannon Authorised Service Agencies. (Please refer to the list of authorised service agents in this manual.
Safety Warnings Please read this manual before installing and using the heater. What to do if you smell gas 9 No gas to burner. • The gas valve should open at the same time as the igniter sparks. If there is no gas to the burner when this occurs check the solenoid coils for continuity. • Check that the gas pressure is present at the test point when the spark is being generated. • Check that there is gas to the inlet of the gas control. 10 Appliance lights but goes into lockout.
Troubleshooting 9. The appliance should be inspected prior to use, with regular inspections (annually) to be made by a licensed service person. It is important that circulating air passageways of the appliance be kept clean, dirt and lint free, for a safe and efficient operation of the heater. To check the operation of the electronic (module) controller (Type 537 ABC) you will require a digital multimeter with the functions to measure AC/DC voltage, continuity, resistance and micro-amps.
User instructions Operating instructions 1. Plug the power cord into the wall socket and turn on the power to the heater, see figure 1. Use of an extension cord is not recommended Wiring diagram 1 2. For control lay-out refer to figure 2 2 3. To turn heater on press switch to POWER ON position. There is a 5 second delay before the burner ignites. At this setting the burner is on LOW and the fan speed is on LOW. Refer figure 3. The burner will ignite on both HIGH and LOW settings. 3 4.
Service Instructions General 1. Service work to be carried out by a licensed service person only. 5. To increase the fan speed to MED, press switch for MED setting. Refer figure 5. 2. Unplug from wall socket. 3. Always shut off the gas supply and ensure that the heater is cool before commencing any service operations. 4. Always check for gas soundness after servicing. Access to components Remove the pedestal front by unscrewing two screws. Refer figure 11. 5 To replace the gas control 1.
User instructions continued Cleaning. All cleaning should be carried out when the heater is cold. Normally the heater should only need wiping with a lint - free damp cloth. Any stubborn stains can be removed with a non-abrasive spray on cleaner. If an abrasive cleaner is used the paint finish will be damaged. Internally the heater should only be cleaned by a licensed service person listed in this manual.
Flue installation Heater Specifications This heater is a flued appliance. It must be properly connected to a flue system in accordance with the latest edition of the Gas Installation Code, AS 5601/AG 601. If elbows are needed, the total horizontal length depends on the number of elbows used. Venting should never slope down. A 6mm per 500mm horizontal rise is recommended. If practical locate the heater in a position to minimise the use of horizontals and elbows.
Installation Instructions 1. This appliance is to be installed by a licensed service person only. 2. This appliance is to be installed in accordance with the manufacturer’s installation instructions, AS 5601/AG 601, Municipal Building Codes, Electrical Wiring Regulations and any other statutory regulations. Clearances 3. Ensure the minimum clearances to combustible construction are maintained during installation, including adequate space for the proper operation and servicing of the heater.
Installation instructions continued To check control outlet pressure at burner ‘Full on” and ‘Low Flame” positions remove the plastic cap from the regulator adjustment location as indicated in figures 22 (a) & (b). 11 12 22 Gas pressure point 18 The pressure point is closed with a captive screw. Turn screw 6 revolution anticlockwise to open the pressure point as indicated on figure 23 (a) and place manometer tube over the test point as per figure 23 (b). 9.
Installation instructions continued Gas connection 12. Connect incoming gas supply pipe at gas control inlet. The inlet fitting is located 150mm in from the rear pedestal wall RH side. Refer figure 15. b) Place log No.2 onto the 2 left back pins. Refer figure 18. 18 c) Place log No.3 on single right front pin, ensure fork locates over log No. 2. Refer figure 19. 15 Fuel bed and log installation 19 13. The fuel bed is contained within the burner chamber. Remove the fuel bed transit packaging.
Installation instructions continued Gas connection 12. Connect incoming gas supply pipe at gas control inlet. The inlet fitting is located 150mm in from the rear pedestal wall RH side. Refer figure 15. b) Place log No.2 onto the 2 left back pins. Refer figure 18. 18 c) Place log No.3 on single right front pin, ensure fork locates over log No. 2. Refer figure 19. 15 Fuel bed and log installation 19 13. The fuel bed is contained within the burner chamber. Remove the fuel bed transit packaging.
Installation instructions continued To check control outlet pressure at burner ‘Full on” and ‘Low Flame” positions remove the plastic cap from the regulator adjustment location as indicated in figures 22 (a) & (b). 11 12 22 Gas pressure point 18 The pressure point is closed with a captive screw. Turn screw 6 revolution anticlockwise to open the pressure point as indicated on figure 23 (a) and place manometer tube over the test point as per figure 23 (b). 9.
Installation Instructions 1. This appliance is to be installed by a licensed service person only. 2. This appliance is to be installed in accordance with the manufacturer’s installation instructions, AS 5601/AG 601, Municipal Building Codes, Electrical Wiring Regulations and any other statutory regulations. Clearances 3. Ensure the minimum clearances to combustible construction are maintained during installation, including adequate space for the proper operation and servicing of the heater.
Flue installation Heater Specifications This heater is a flued appliance. It must be properly connected to a flue system in accordance with the latest edition of the Gas Installation Code, AS 5601/AG 601. If elbows are needed, the total horizontal length depends on the number of elbows used. Venting should never slope down. A 6mm per 500mm horizontal rise is recommended. If practical locate the heater in a position to minimise the use of horizontals and elbows.
User instructions continued Cleaning. All cleaning should be carried out when the heater is cold. Normally the heater should only need wiping with a lint - free damp cloth. Any stubborn stains can be removed with a non-abrasive spray on cleaner. If an abrasive cleaner is used the paint finish will be damaged. Internally the heater should only be cleaned by a licensed service person listed in this manual.
Service Instructions General 1. Service work to be carried out by a licensed service person only. 5. To increase the fan speed to MED, press switch for MED setting. Refer figure 5. 2. Unplug from wall socket. 3. Always shut off the gas supply and ensure that the heater is cool before commencing any service operations. 4. Always check for gas soundness after servicing. Access to components Remove the pedestal front by unscrewing two screws. Refer figure 11. 5 To replace the gas control 1.
User instructions Operating instructions 1. Plug the power cord into the wall socket and turn on the power to the heater, see figure 1. Use of an extension cord is not recommended Wiring diagram 1 2. For control lay-out refer to figure 2 2 3. To turn heater on press switch to POWER ON position. There is a 5 second delay before the burner ignites. At this setting the burner is on LOW and the fan speed is on LOW. Refer figure 3. The burner will ignite on both HIGH and LOW settings. 3 4.
Troubleshooting 9. The appliance should be inspected prior to use, with regular inspections (annually) to be made by a licensed service person. It is important that circulating air passageways of the appliance be kept clean, dirt and lint free, for a safe and efficient operation of the heater. To check the operation of the electronic (module) controller (Type 537 ABC) you will require a digital multimeter with the functions to measure AC/DC voltage, continuity, resistance and micro-amps.
Safety Warnings Please read this manual before installing and using the heater. What to do if you smell gas 9 No gas to burner. • The gas valve should open at the same time as the igniter sparks. If there is no gas to the burner when this occurs check the solenoid coils for continuity. • Check that the gas pressure is present at the test point when the spark is being generated. • Check that there is gas to the inlet of the gas control. 10 Appliance lights but goes into lockout.
Notes Warranty The Cannon appliance is warranted against defects in materials and workmanship for a period of one, (1) year from its date of original purchase, for residential use in Australia. Warranty service, which includes parts and labour for the replacement or repair of defective parts, is available through Cannon Authorised Service Agencies. (Please refer to the list of authorised service agents in this manual.
Notes Contents Contents 2 Warranty 3 Safety warnings 4-5 ❍ What to do if you smell gas ❍ Warnings ❍ Standards User instructions 6-8 ❍ Operating instructions ❍ Cleaning Heater specifications Installation instructions ❍ ❍ ❍ ❍ ❍ ❍ 9 10-15 Clearances Installation Gas connection Fuel bed & log installation Gas control Gas pressure point Flue installation 16-17 ❍ Flue kit Service instructions 18-19 ❍ General ❍ Access to components To replace the gas control To replace the fan To replace the electr
MAKER’S WARRANTY Cannon FITZROY PROFILE FREESTANDING MODELS FITZP, FITZLP Cannon FITZROY PROFILE USER INSTRUCTIONS INSTALLATION INSTRUCTIONS Part No: F2774 Revision C SERVICE INSTRUCTIONS This heater is approved for use with Natural and Propane gases.