Specifications

1. The burner is contained within the burner
chamber. Refer figure 15.
2. Carefully unpack the log set. Logs are
numbered as follows:
#1 - Left front log
#2 - Left back log
#3 - Right front log
#4 - Right back log
Position the four individually numbered logs in the following order on the burner head as
shown in figure 16-19. The male locating pins on burner head must engage with
corresponding holes in the individual logs.
a) Place log #1 into the 2 front left pins on the burner
head, ensuring that the charring faces the front.
Refer figure 16.
b) Place log #2 onto the 2 left back pins. Refer figure
17.
c) Place log #3 on single right front pin, ensure fork
locates over log #2. Refer figure 18.
d) Place log #4 on single right back pin, ensure left side
of log rests on depression in #3 log. Refer figure 19.
3. Refit the inner glass, making sure not to over tighten
the screws.
4. Reconnect switch loom to the fascia switch set.
5. Replace the fascia.
6. Connect plug to the wall socket and switch it on.
15
14
The heater is supplied with a flexible power cord with a plug fitted.
A 10 Amp powerpoint (socket) must be located within 1.5m of the heater.
For installations where the powerpoint is located outside of the enclosure, locate
the power cord in the fascia cut out on the left or right hand side as required.
For a power supply connection located inside the enclosure run the power cord
through the cord access located on the rear panel at the lower left hand side by
pushing the cord access plate from the bottom.
The rubber grommet that is fitted over the cord must be located correctly in the
cut out of the cord access plate (see figure 20).
Restore the cord access plate to the original position and seal with an appropriate
removable material, this is especially important when the installation is in a
chimney with no flue fitted to eliminate the possibility of any leakage of flue
products into the room.
A suitable double pole isolation switch must be installed externally for servicing or
emergency shut down of the heater.
All fixed wiring must be installed by a suitably qualified person and comply to the
appropriate electrical wiring rules and gas installation standards.
Electrical Connection
This appliance is designed to operate on 240V AC power supply. Failure to
operate unit at correct supply voltage may created unsafe conditions.